My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 2:02:53 PM
Creation date
11/7/2018 12:28:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\824\PR0231459\COMPLIANCE INFO 2013 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
2/21/2017 6:51:40 PM
QuestysRecordID
3341688
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • Page of <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Specify,) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: INCON Equipment Resolution:.0001 <br /> UDC#3/4 UDC#7/8 UDC# UDC# <br /> UDC Manufacturer: Unk Unit <br /> UDC Material: Fiber Fiber <br /> UDC Depth: 24" 24" <br /> Height from UDC Bottom to Top - 10" 10" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 12" 12" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Clean/Dry Clean/Dry <br /> testing: <br /> Portion of UDC Tested' 18" 18" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No DNA ❑Yes ❑No ❑NA <br /> product and water)?' <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> safe shutdown?" <br /> Was fail-safe verified to be ❑Yes ❑No ❑NA O Yes D No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational?' <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1207 1241 <br /> Initial Reading(R): 6.0189 4.9976 <br /> Test End Time: 1222 1256 <br /> Final Reading(RF): 6.0190 4.9971 <br /> Test Duration: 15 min 15 min <br /> Change in Reading(RF-RI): .0001 .0005 <br /> Pass/Fail Threshold or Criteria: .002 .002 <br /> Test Result: 0 Pass ❑FaR ® Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> as a <br /> Was sensor properly replaced and ❑yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after test ng? <br /> Comments— (include information on repairs madeprior to testing, and recommended follow-up for failed tests) <br /> FEB 1 1 2014 <br /> HEA1111 DEPAMMENT <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />