1 <br /> ' LETTER REPORT —WASTE OIL TANK SITE ASSESSMENT <br /> POSDEF Power Company, 2526 West Washington Street, Stockton <br /> October 29, 1998 <br /> Page two <br /> On or about April 19, 1998, the tank was inspected and tested. The test indicated that <br /> the secondary containment had failed; however, the primary containment had not failed. <br /> The source of water in the interstitial space resulted from the secondary containment <br /> failure and the high groundwater beneath the site. Based on these findings, POSDEF <br /> began to formulate a plan to abandon the tank in place. The decision to abandon the <br /> tank in place rather than removing the tank is based on the close proximity of a concrete <br /> pedestal that structurally supports a large turbine. As such, tank removal would <br /> compromise the structural integrity of this power generating source. <br /> Scope of Work <br /> The objective of this project was to collect soil and possibly groundwater-grab samples <br /> in close proximity to the bottom of the tank, at a depth of approximately five (5) feet, to <br /> assess the potential for in-place closure. To achieve this objective, two soil borings <br /> were advanced with a hand auger as close to each end of the tank as possible. <br /> To access the subsurface soil at both soil boring locations, the 16-inch thick concrete <br /> surface was first cored by Cal-West Concrete Coring. The first soil boring (SB-1) was <br /> positioned approximately one foot south of the southwest corner of the tank. An <br /> aboveground clean oil tank and aboveground piping prevented access to the west end <br /> of the tank. The second soil boring (SB-2) was positioned approximately two feet east <br /> 1 of the eastern end of the tank. Aboveground piping prevented closer access to the end <br /> of the tank. The locations of both soil borings are shown on Figure 1. <br /> In accordance with the attached PHS/EHD drilling permit, both soil borings were <br /> advanced with a hand auger to a total depth of approximately five feet below ground <br /> surface (bgs). At the total depth of five feet, a soil sample was collected from both soil <br /> borings using a slide hammer lined with a brass sleeve. The sample sleeve was capped <br /> with Teflon® sheets and plastic end caps, labeled, and stored in an iced cooler for <br /> transport under chain-of-custody documentation to GeoAnalytical Laboratories, Inc. <br /> (GeoAnalytical), a state of California certified hazardous waste testing laboratory <br /> (Certification #1157). <br /> GeoAnalytical analyzed both soil samples for Total Petroleum Hydrocarbons (TPH)-as- <br /> ' gasoline, TPH-as-diesel, TPH-as-kerosene, and TPH-as-motor oil by EPA 8015M, <br /> benzene, toluene, ethylbenzene and xylenes (BTEX) by EPA Method 8020M, <br /> chlorinated hydrocarbons by EPA Method 8240, metals (Cadmium, Chromium, Lead, <br /> Nickel and Zinc) by EPA Methods 6010 and 7420, and PCBs by EPA Method 8080. <br /> 1 <br />