Laserfiche WebLink
San Joaquin County Environmental Health Department1868 East Hazelton Avenue, Stockton, California 9520::77T <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: <br /> QUICKI KLEEN CAR WASH Date: <br /> 707E YOSEMITE AVE, MANTECA October 09, 2017 <br /> UST System Observations <br /> 125CCR <br /> E2631.1 <br /> Unburied below grade UST system failed to meet exemption status <br /> oV OR oC05 <br /> Tampered with red tag <br /> MV OR oCOS <br /> Deposited petroleum into a red tagged UST <br /> MV oR aCOS <br /> Tampered with or disabled leak detection devices or alarmsoV oR oC05 <br /> UST system not compatible with the substance stored o V OR D COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements <br /> OV OR o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V OR o COS <br /> L330 CCR 2636(x(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 4CCR2643(d) <br /> jDaily <br /> ction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> iennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> ennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284 No permit to operate. <br /> A permit to operate the UST system has not been issued due to outstanding violations that have not been <br /> addressed. No person may own or operate an UST unless a permit for its operation has been issued by the local <br /> agency to the owner or operator of the UST system. Immediately obtain a permit to operate a UST system from the <br /> EHD. <br /> This is a Class I violation. <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually.The current"Certificate of Financial Responsibility"and the"Letter from Chief <br /> Financial Officer' is dated 11/28/14. Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/,and upload the required documents. <br /> This is a repeat violation, Class II. <br /> FADG07815 PRO505151 SCO01 10/09/2017 <br /> EHD 23-01 Rev.0912916 <br /> Page 3 of 7 underground Storage Tank Program OR <br />