My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 9:23:19 AM
Creation date
11/7/2018 1:13:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\Y\YOSEMITE\707\PR0505151\COMPLIANCE INFO 2016 - PRESENT .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.orcil <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICK[ KLEEN CAR WASH 707 E YOSEMITE AVE, MANTECA October 09, 2017 <br /> UST System Observations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status in V o R o COS <br /> 324 CCR 2717.1(9) Tampered with red tag o V MR o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored 0 V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V 0 R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements in V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V 0 R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V MR o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(preJanuary 1984) in V o R u COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1964) V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documenlabon violation .i V v R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V MR 0 COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284 No permit to operate. <br /> A permit to operate the UST system has not been issued due to outstanding violations that have not been <br /> addressed. No person may own or operate an UST unless a permit for its operation has been issued by the local <br /> agency to the owner or operator of the UST system. Immediately obtain a permit to operate a UST system from the <br /> EHD. An"Operating without a Permit"penalty applies. <br /> This is a Class I violation. <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br /> are required to be submitted annually.The current"Certificate of Financial Responsibility"and the"Letter from Chief <br /> Financial Officer" is dated 11/28/14. Immediately log into the California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov/,and upload the required documents. <br /> This is a repeat violation, Class II, <br /> FA0007815 PRO505151 SCO01 10/0912017 <br /> EHD 23-01 Rev.0922116 Page 3 of 7 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.