Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Oate: <br /> QUICKI KLEEN CAR WASH 707 E YOSEMITE AVE, MANTECA October 09, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information fors for both 87 grade tanks and the Diesel tank are not current in CERS. <br /> It is documented in CERS that there is no riser pipe secondary containment. During the inspection,fiberglass <br /> secondary containment was observed for the riser. <br /> Additionally, in the Diesel tank information plans, it is documented that there is vapor recovery primary and <br /> secondary piping. Vapor recovery piping was not observed for the Diesel tank. <br /> The monitoring plan indicated external audible/visual as an overfill protection in addition to the fill tube shut-off valve, <br /> no external audible visual alarm was observed at the time of inspection. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and not approved by the EHD. It is documented that UDC(under dispenser <br /> containment) monitoring stops flow of product at the dispenser. It was observed that UDC monitoring triggers <br /> automatic pump shutdown. The monitoring plan must be uploaded to the California Environmental Reporting <br /> System(CERS). Immediately log into CERS,make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class IL <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 10/11/16 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 11/10/16. This information has <br /> not been received resulting in a non-compliant status for this facility. An operator that receives an inspection report <br /> shall have 30 days to submit a written response that includes a statement documenting corrective actions taken or <br /> proposing corrective actions which will be taken. Ensure that a written response documenting corrective actions <br /> taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> FA0007815 PR0505151 SCO01 10/09/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 7 Underground Storage Tank Program OIR <br />