My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
334
>
2300 - Underground Storage Tank Program
>
PR0231665
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:44:20 PM
Creation date
11/7/2018 4:53:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231665
PE
2361
FACILITY_ID
FA0003714
FACILITY_NAME
LACHHAR CHEVRON*
STREET_NUMBER
334
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26115041
CURRENT_STATUS
02
SITE_LOCATION
334 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\334\PR0231665\BILLING 1985 - 2004.PDF
QuestysFileName
BILLING 1985 - 2004
QuestysRecordDate
3/3/2017 12:45:56 AM
QuestysRecordID
3347324
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• WwGC! <br /> STATE OF CALIFORNIA • "`� Got <br /> STATE WATER RESOURCES CONTROL BOARD sy y <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED <br /> "P"ERMIIT�� ❑ 6 TEMPORARY TANK CLOSURE ❑ B TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: l vZ u,-� ��'S - — �4-5 2- <br /> 1. <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.0.R ''J B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) ! C� D. TANK CAPACITY IN GALLONS: 01) <br /> II.TANK CONTENTS IF AA IS MARKED,COMPLETE ITEM C. <br /> A tK 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ to PEGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> 10 MIDGRADE UNLEADED 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED H 99 OTHER(DESCRIBE IN ITEM D.BELOT <br /> D. IF(A1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A_S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF u I DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAU,LLTT/ ❑ 99 OTHER <br /> B. TANK F—] 1 BARE STEEL ❑ 2 STAINLESS STEEL XI 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL F-15 CONCRETE r76 POLYVINYL CHLORIDE �❑\ 7 ALUMINUM ❑ 8 1W% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING \E2�,B UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 1001A METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BIC. SPILL CONTAINMENT INSTALLED(YEAS OVERFILL PgEVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO STRIKERPLATE YES (_/ NO_ DISPENSER CONTAINMEN VES NO <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A6(12 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 MECNIHIGL UNE U91N ❑2 NNE TNiH M 3 C TNUWG INIERSTIfMI 4 ELECTRONIC UNE 5 AUTOWTIC NW ❑ 99 OTHER <br /> OETECfOR iE5TN6 WWMING LEAN OETECfOR 9#ITWWN <br /> V.TANK LEAK DETECTION A��.. <br /> F-11 VISUAL CHECK 2 RECONCILIATIONMANUAL ORY ❑ 3 MONITORING VADOZE 4 GAUGING AUTOMATIC TANK ❑5 MONITORING GROUND WATER <br /> ONTORINGTER ❑ 6 TTEESTINGNUAL TANK <br /> 7 <br /> CONTINUOUS MONITORING INTERSTITIAL ❑ 8 SIR ❑ 9 WEEK LGY INUAL ❑10 STINGY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE g5ST OF MY KNOWLEDGE, IS TRU A CORRECT <br /> _79N* & S DATE <br /> (PRINTED&SIG <br /> DSIGNANAE) <br /> U S U <br /> LOCAL AGENCY USE ONLY THE STATE I.D M R IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COU JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# m <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLN-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT P LE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THF&RGROUND STORAGE TANK REGULATIONS <br /> FORMS (6.95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.