My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
2300 - Underground Storage Tank Program
>
PR0231667
>
COMPLIANCE INFO 2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2019 4:23:22 PM
Creation date
11/7/2018 5:08:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0231667
PE
2361
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
01
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\4075\PR0231667\COMPLIANCE INFO 2014-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e3of8 <br />Wr San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: WWW.sjqov.org/ehqd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />_. _. <br />Date: <br />UST System Observations <br />319 HSC <br />25291(a) <br />water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />■ V ❑ R ❑ COS <br />HSC <br />25290.1(c3) <br />CCR <br />25290 1(03). <br />2636(c)(1) <br />Secondary containment not constructed to prevent water intrusion <br />All releases in secondary piping do not flow to a collection sump <br />o V ❑ R ❑ COS <br />❑ V ❑ R ❑COS <br />CCR <br />k32 <br />2636([)(2) <br />Line leak detector not installed <br />❑ V ❑ R ❑ COS <br />CCR <br />2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />o V ❑ R ❑ COS <br />CCR <br />2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V ❑ R ❑COS <br />325 CCR <br />2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R o COS <br />326 CCR <br />2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />o V ❑ R o COS <br />327 HSC <br />25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R ❑COS <br />328 CCR <br />2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑COS <br />329 <br />CCR 2717.1(1) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑COS <br />5299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑COS <br />2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑COS <br />25298(b) <br />Failed to comply with temporary closure requirements <br />oV OR oCOS <br />25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />FCCR2W(e) <br />Non -Pressurized Piping <br />2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑COS <br />2643(d) <br />Triennia10.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R o COS <br />2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑COS <br />Other Violations <br />2010 <br />See below <br />Unlisted AdministrationlDocumentationviolation <br />oV OR ❑COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />o o oCOS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑V o ❑COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />Received by <br />(initial): QM <br />Inspector: <br />Pe <br />Phone: <br />Date: <br />e3of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.