My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
2300 - Underground Storage Tank Program
>
PR0231667
>
COMPLIANCE INFO 2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2019 4:23:22 PM
Creation date
11/7/2018 5:08:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0231667
PE
2361
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
01
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\4075\PR0231667\COMPLIANCE INFO 2014-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wr San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www sigov ora/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to comply) <br />Item # <br />Remarks <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />line leak detector was identified on the <br />106 <br />The monitoring plan is not current and/or not approved by the EHD. Inaccurate <br />91 UST monitoring plan. The monitoring plan must be uploaded to the California Environmental Reporting <br />-octane <br />System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a Class II violation. <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document L1 alarm from the attached alarm history on the January 13, 2015 <br />The <br />designated operator monthly inspection report and failed to check that it was responded to appropriately. <br />Also, the designated operator failed to note that all <br />missing alarm includes: 1_1 alarm from December 19, 2014. <br />the monitoring system certification conducted on that <br />alarms, which occurred on May 15, 2014, were due to routine <br />date. During the monthly inspection, the designated operator shall review the alarm history for the previous month, <br />check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performinq <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a Class 11 violation. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The 91 -octane STP sump sensor was located 3-4 inches up the sump saddle and not located to detect a leak at the <br />to be able to detect a leak at the earliest possible <br />earliest opportunity. Monitoring equipment shall be maintained <br />opportunity. The sensor was relocated to the lowest point of the sump by the service technician. Ensure that all <br />monitoring equipment is maintained to detect a leak at the earliest opportunity. This was corrected on site. <br />This is a Class II violation. <br />309 <br />CCR 2636(0(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />failed to stop the flow of product at the <br />The Bravo box float and chain in the UDC 718 sump (87 -octane product) <br />All equipment shall be maintained to activate an audible and visual alarm or stop <br />dispenser when tested. monitoring <br />the flow of product at the dispenser when it detects a leak. The service technician adjusted the chain(s) and verified <br />functionality. This was corrected on site. <br />This is a Class II violation. <br />319 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 87 -octane STP sump. If water could enter into the secondary containment by precipitation <br />technician removed approximately 0.5 -gallons <br />or infiltration, it must be removed and disposed of properly. The service <br />annular spaces are maintained free of liquid. This was <br />of liquid from the 87 STP sump. Ensure that all sumps and <br />corrected on site. <br />This <br />Received by <br />Inspector: <br />= `AANZO, RENS <br />Phone: <br />209 953-7699 <br />( ) <br />Date: <br />(initial): <br />age 4 OT 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.