Laserfiche WebLink
UST SYSTEM PRINTSET INFORMATION <br /> 1. �rj//� Four complete sets of plans (To inc Lude specification sheets and/or equipment brochures if not on file). <br /> 2. tOIL- Plans drawn to scale in non-erasable print. <br /> 3. Plot plan to show Location and rxnber of tanks. <br /> 4. V& Tank cross-sectional diagram included on prints submitted. <br /> 5. fIK ✓ Detail of tank, piping System, excavation and cover. 1m�L x✓ !7 v.a4. <br /> 6. �.��'- � Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br /> Article 3, Sec. 2631 (r) & 26351 <br /> Verification of product conpatibility with the tank(s), piping, monitoring <br /> device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)] <br /> 8. / i Manufacturers written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)] <br /> 9. . Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br /> [Section 2635 (b) (6) & (7)] <br /> 10. Double walled tanks using pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)] <br /> 11. NFPA 329 "Precision Test" required upon coapletion of installation with tank in operating condition. Test results to <br /> be submitted directly to PHS/EHD from the testing company or owner of facility. [Health & Safety Code, Division 20, <br /> Chapter 6.7, Section 25291 (g)] <br /> 12. TANK COMPOSITION <br /> TANK # It ' C ,Z k # # <br /> CAPACITY (2.0(D0 lo000 <br /> MANUFACTURER MoD EE" fv\p-OGq,N <br /> OmuO tC Dew a�E <br /> COMPOSITION u+ww STEEL ww.,� STG£� <br /> MODEL <br /> u.+..:aocl) <br /> PRODUCT GASOI�uC D��.b3wd 2. <br /> CORROSION PROTECTION f7'bCL(- A%5 Fi$Ef-/e�NSs <br /> U.L. LISTED <br /> COMPATIBILITY WITH 100% <br /> METHANOL 7 L S L?S <br /> 13. TANK(s) TO BE INSTALLED <br /> ✓^ v A. Steel-clad with fiberglass reinforced plastic. <br /> ±4A B. Holiday test required immediately before --setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)] <br /> Nom- C. Fiberglass [Sections 2635 (3) and 2631 (p)] <br /> (1) Striker plate dimensions and materials. <br /> (2) Striker plate under all accessible openings. <br /> (3) Installation instructions require an air test and soap bubble test prior to installation. <br /> D. Non-clad steel tank [Section 2635 (b)] <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br /> etc.). <br /> (2) Approved by a corrosion engineer or N.A.C.E. technician. <br /> (3) Document stating inspection method and frequency (m]nimm semi-annual inspection requirement). <br /> 4 <br />