Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
INSTALL_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 1:12:59 PM
Creation date
11/7/2018 8:18:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MYRTLE\2849\PR0538822\INSTALL\2015 INSTALL SR0069410\GENERAL INSTALL PAPERWORK.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V � <br /> IR! • •• Intro <br /> INTRODUCTION • These instructions provide the minimum requirements <br /> The purpose of this manual is to provide detailed for the successful installation of a fiberglass <br /> instructions for installing Containment Solutions, Inc. underground storage tank under normal conditions. <br /> (CSI)single and double-wall fiberglass underground Containment Solutions does not design or engineer <br /> storage tanks and oil/water separators, the actual installation.The owner's Engineer of <br /> Record for the installation can exceed these minimum <br /> If you do not have the proper experience and you have requirements and is responsible for the final design. <br /> not completed CSI training for tank installation in the last . The presence of any Containment Solutions <br /> 24 months, please contact a licensed contractor, representative e f the o site does not relieve the <br /> or call CSI for a list of trained contractors. P j <br /> contractor of responsibility to follow these installation <br /> These instructions have been developed and refined instructions. <br /> from the experience of over 300,000 tank installations. <br /> Proper installation is required to assure the long-term TANK WARRANTY ACTIVATION <br /> performance of CSI Storage Tanks.These instructions • These instructions must be followed. <br /> must be followed • The Tank Installation Checklist(Pub. No. INST 6002) <br /> SAFETY must be properly completed and signed by the tank <br /> o <br /> owner's representative and the installing contractor. <br /> These instructions should not interpreted in any - The Tank Installation Checklist,these instructions and <br /> way to put one's health at risk, or to harm property y P <br /> and/or the environment. an correspondence related to the tank installation <br /> must be retained by the tank owner and provided to <br /> The following definitions will serve as a guide when CSI to validate any future warranty claim. <br /> reading this manual: • The warranty in effect at the time of tank delivery will <br /> I U-� apply and is available from Containment Solutions. <br /> Indicates a potentially hazardous situation,which BEFORE YOU BEGIN <br /> if not avoided could result in death or serious injury. • Read, understand and follow these instructions. <br /> • Barricade the tank area until the job is completed. <br /> • Review and prepare to complete the installation <br /> checklist. <br /> Indicates a potentially hazardous situation,which if - Check with local authorities for building codes, <br /> not avoided may result in minor or moderate injury. underground utilities and testing requirements. <br /> • If you have installation questions or need alternate <br /> U o installation methods, contact CSI Tank Technical <br /> Indicates a potentially hazardous situation,which if Support. <br /> not avoided may result in property damage. • If you have other questions regarding tank <br /> modifications, such as adding fittings or manways <br /> or tank repair, contact Containment Solutions <br /> IMPORTANT INFORMATION Field Service. <br /> Proper installation of each tank is essential: • A list of supplemental documents is found <br /> • To ensure the safety of all the individuals involved in Section R. <br /> in the tank installation. t - <br /> • To prevent tank damage and/or failure,which <br /> could lead to product loss and environmental Do not stand on or under tank while tank is being <br /> contamination. lifted.This could result in personal injury or death. <br /> • To validate the tank structural warranty. <br /> IMPORTANT REMINDERS Do not enter tank or sumps unless following OSHA <br /> • In addition to these instructions,the installation must guidelines for confined space entry. Failure to <br /> comply with NFPA(30, 30A,and 31), OSHA and follow OSHA guidelines could result in death or <br /> all applicable Federal, State, Local,or Provincial, serious injury. <br /> construction, safety and environmental codes and <br /> regulations. <br /> • Any variances or deviations which are in direct �; Q <br /> conflict with these published installation instructions <br /> must be approved in writing prior to the installation . <br /> by Containment Solutions Tank Technical Support. <br /> ASPHYXIATION FIRE EXPLOSION <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.