My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
INSTALL_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 1:12:59 PM
Creation date
11/7/2018 8:18:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MYRTLE\2849\PR0538822\INSTALL\2015 INSTALL SR0069410\GENERAL INSTALL PAPERWORK.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Anchoring cont. (Wire Rope - . . H <br /> �.. When connecting the end of a hold-down strap to the Refer to Table H-6 for minimum wire rope diameter <br /> anchor, common methods include: (see Figure H-4) and strength. <br /> • Drop-forged turnbuckle(A) <br /> • Looped wire rope (B) TABLE H-6 <br /> • Combination of both A and B(C) Wire Rope <br /> • After hardware is installed,all exposed metal on the Tank Minimum Minimum <br /> P Diameter Diameter Ultimate Strength <br /> anchoring system must be coated or galvanized to <br /> protected against corrosion. 4' '/s" (10mm) 13,120 lbs(5,951 kg) <br /> Figure H4 6', 8', 10', 12' %2' (13mm) 23,000 lbs(10,433 kg) <br /> • Follow recommendations of the wire rope <br /> manufacturer,as well as all industry standards when <br /> selecting, handling,attaching or connecting wire rope. <br /> • Tighten all hardware uniformly and follow the <br /> JA B JC manufacturer's torque specifications. Double check <br /> the tightness once the anchoring system is complete. <br /> When forming a loop in the wire rope, a splice is <br /> required for connecting the two ends together. Use <br /> a minimum of four clamps for 3/a'wire rope and a <br /> ,£ minimum of six clamps for 1/2"wire rope. Place the <br /> rope ends parallel to each other and install the clamps <br /> DROP-FORGED TURNBUCKLES as shown in Figure H-7. <br /> May be used in place of all or a portion of wire rope Figure H-7 <br /> described in this section. <br /> TABLE H-5 <br /> `►� Tank Minimum Turnbuckle Diameter(by type) 3B"Wire Rope/Clamp Alignment <br /> Minimum <br /> Dia. Hook Jaw Eye Working <br /> Load Limit' <br /> 4' '/2' 1,200 lbs IQ"Wire Rope/Clamp Alignment <br /> 6' 1 3/;' 1/2' '/2' 22,200 lbs <br /> 8' 23/4" 3 " 3/4" 5,200 lbs <br /> 10' 23/," 3/." 3/" 5 200 lbs DEADMEN ANCHORS <br /> 12' 23/4' 3/," 3/+" 5,200 lbs Deadmen are made of reinforced concrete,designed <br /> according to the American Concrete Institute(ACI)code, <br /> ultimate load should be 5 times working load limit at least 12'long, placed end to end equal to tank length, <br /> and with at least two anchor points per deadman. <br /> WIRE ROPE • Refer back to Table A-5 for CSI deadmen <br /> dimensions and weight. <br /> • • Each tank requires its own deadman on both sides, <br /> or if one deadman is used between adjacent tanks, <br /> Wire rope should never be in direct contact with any it must be doubled in width. <br /> portion of the tank or damage may occur. • A separate anchor point must be provided for each <br /> strap. <br /> • A method to use wire rope on the ribs over the tank . CSI deadmen are engineered and sized to the tank <br /> top is available(see Supplemental Documents, ordered. <br /> Section R). <br /> • Use 6 x 19 Improved Plow Steel IWRC, or better,wire ' Placement of CSI deadmen is the same as standard <br /> rope. deadmen. <br /> • Lay the deadmen in the excavation parallel to the <br /> tank and outside of the tank shadow <br /> (see Figure H-8). <br /> 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.