My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
INSTALL_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 1:12:59 PM
Creation date
11/7/2018 8:18:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MYRTLE\2849\PR0538822\INSTALL\2015 INSTALL SR0069410\GENERAL INSTALL PAPERWORK.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground pipe is welded DW steel manufactured by Rovanco (Exhibit <br /> 4). All seconddry pipes will be under vacuum and monitored by the <br /> Veeder-Root. The system also has an aboveground filter room where the <br /> system goes from underground to aboveground. The filter room has an 8" <br /> concrete floor with a 6"containment berm with a low point Veeder-Root <br /> sensor. <br /> Gasoline Fueling System <br /> Peterson Hydraulics, Inc. (PHI)will be installing one (1) 10,000 gallon <br /> double-wall FRP Containment Solutions gasoline fuel tank. Fueling will <br /> take place outside the Fuel Brake Building with one (1) 22 GPM standard <br /> flow Gasboy dispenser. Pumps include two (2)FE Petro 2 hp VST <br /> turbines with leak detectors. Dispenser will be controlled with the <br /> Fleetwatch Fuel Management System. The system will be monitored with <br /> a Veeder-Root TLS 350 for code compliance. Double-wall containment <br /> sumps will be installed under the dispenser,tank sumps, and vent pipe <br /> transitions. Underground piping is double-wall Smith FRP pipe. <br /> Phase I Vapor Recovery is accomplished with the OPW two-point system <br /> (VR-102-L) and Phase 11 is the Healy Vapor Systems Phase II Enhanced <br /> Vapor Recovery(EVR) System with a Healy Clean Air Separator at the <br /> vent riser and vacuum pump under the dispenser (VR-204-M). <br /> Diesel Generator Fueling System <br /> Peterson Hydraulics, Inc. (PHI)will be installing one (1) 4,000 gallon <br /> double-wall Containment Solutions UL2085 diesel fuel tank with top fill, <br /> emergency vents, vents, anti-siphon and all tank trim. Tank inventory and <br /> leak detection will be monitored by a Veeder-Root tank monitoring <br /> system. All piping is aboveground single wall sch. 40 B.I. pipe. <br /> PHI's design is based on a similar facility which we constructed for the Orange County <br /> Transit District. With the high flow and volume pumped through the system, individual <br /> filters at the dispensers will clog and restrict fueling. Large filters similar to ones you see <br /> for aircraft fueling are required. The filters are installed aboveground in a containment <br /> room with a concrete floor and 6"beam. Once the pipe goes aboveground in the filter <br /> room we cannot go back underground and meet code requirements for line leak detection <br /> on underground pipe. If filters were installed underground in a sump, line leak detectors <br /> still would not function properly because of the filter and confined space entry would be <br /> required to enter the sump to change the filters. So to meet line leak detection <br /> requirements we isolate the underground pipe from the filter with a solenoid valve right <br /> after we leave the underground transition sump. The solenoid opens when pumps turn on <br /> and close when pumps are shut down. After the filters we utilize the Rovanco DW <br /> aboveground welded steel pipe to the dispensers. In addition, if the filtering issue did not <br /> exits piping inside the building would have to be greater than 5' deep and the tank bury <br /> depth would be approximately 9 feet deep. This would mean a confined space entry for <br />