My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 2:28:08 PM
Creation date
11/8/2018 9:36:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LODI\2500\PR0231356\COMPLIANCE INFO 1998-2006.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'SWRCB January,2002 • 0 Page_of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By:. ❑Tank Manufacturer ❑ Industry Standard ❑ Professional Engineer <br /> ❑Other(Spceify) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑ Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank# Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑ No <br /> Tank Capacity: 12000 12000 6000 6000 <br /> Tank Material: <br /> Tank Manufacturer: DW Steel DW Steel DW Steel DW Steel <br /> Product Stored: Unleaded Unleaded Plus Premium Diesel <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(Ri): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RFRI): <br /> Pass/Fail Threshold or Criteria: <br /> Test Result; ❑Pass ❑Fail E ❑Pass ❑Fail []I Pass ❑ Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes ❑No ❑NA ❑Yes ❑No ❑ NA Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> ❑ <br /> verified functional after testing? [I ❑ ❑ [I ❑Yes No NA Yes No NA Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment,such a <br /> systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment testing. {California Code of <br /> Regulations,Title 23, Section 2637(ax6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.