My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
INSTALL_1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:53:13 AM
Creation date
11/8/2018 9:39:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\INSTALL 1992.PDF
QuestysFileName
INSTALL 1992
QuestysRecordDate
8/2/2017 4:00:35 PM
QuestysRecordID
3544491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installation Ovivew <br /> Fiberglas° underground ' <br /> tanks must be installed in <br /> accordance with the installa- <br /> tion instructions (O/C TANKS r <br /> publication number 3-PE-6304). <br /> This document should be part <br /> of your tank specifications. 4y" <br /> Some key installation steps y , <br /> are highlighted below. See the <br /> published installation instruc- <br /> tions for complete details. <br /> Double-wall tanks must be <br /> mechanically unloaded from <br /> the delivery truck using a <br /> backhoe or crane. <br /> A special air test procedure <br /> is required for double-wall <br /> tanks. A special air test fix- <br /> ture is shipped with the tank. <br /> Fiberglas tanks must be pres- <br /> surized and inspected for leaks <br /> using a soapy water solution. <br /> Leak testing prior to installa- <br /> tion helps insure that Fiberglas If the Hydrostatic Tank Moni- Properly installed, Fiberglas <br /> tanks were not damaged in toring system is activated by underground petroleum <br /> shipment. filling at the jobsite, the tank storage tanks can provide <br /> Installation for double-wall tanks cavity must be filled by pouring extended service in storing <br /> is similar to the procedure for the liquid into the cavity. Use petroleum products without <br /> single-wall tanks. O/C TANKS tap water or an acceptable corrosion-caused leaks and <br /> requires pea gravel backfill antifreeze mixture as the without maintenance. <br /> material; this gravel is a natu- monitoring fluid. <br /> rally rounded aggregate rang- O/C TANKS maintains a listing <br /> ing from 1/8" to 3/4" diameter. All tanks must be vented. of over 1,200 independent con- <br /> If pea gravel is not available, Fiberglas tanks are designed tractors who have been trained <br /> washed stone crushings (1/8" for operation at atmospheric to install Fiberglas tanks. On <br /> to 1/2" diameter) meeting pressure only, except for use request,we can provide names <br /> ASTM C-33 may be used as with vapor recovery systems, of trained contractors. <br /> an alternate. Other backfill provided the pressure or <br /> materials must not be used vacuum does not exceed <br /> without consulting O/C TANKS 1 psi maximum on the primary <br /> for written approval. tank. If the monitoring cavity <br /> between the inner and outer <br /> A minimum of 12" backfill tank is vented, it must be <br /> bedding is required between vented independently from <br /> the tank and the excavation the primary tank. <br /> bottom or concrete anchoring <br /> pad. Tanks must not be For additional details, request <br /> installed on timbers, beams Underground Tank Installations <br /> or cradles. (O/C TANKS publication <br /> number 3-PE-6304). <br /> 27 <br />