Laserfiche WebLink
Double-yMberglasm Long Form: Sectio 1:03 Submittals <br /> Tanks For Fuel Storage Guide Specificatlon A. Shop Drawings: Contractors <br /> Model DWT-213 and O/C TANKS Double-Wall shall submit copies of <br /> DWT-413 Reinforced Polyester shop drawings for each <br /> Underground Storage Tanks tank. Drawings shall include <br /> all critical dimensions and <br /> Part 1 General show locations of all fittings <br /> 1.01 Related Work Specified In and accessories, i.e., man- <br /> Other Sections ways, ladders, hold-down <br /> A. Cast-in-Place Concrete: straps, heating coils, etc. <br /> Section 03300 Materials of construction <br /> shall be in accordance <br /> B. Anchor Bolts: Section with Section 1.02 of this <br /> Specification 05501 specification. <br /> ,,,,,• C. Plastic Pipe: Section 15064 B. Catalog Data: Contractor <br /> shall submit copies of <br /> D. Liquid Level Gauges: manufacturer's literature. <br /> Section 15174 <br /> C. Certification Plate: U.L. <br /> ShortForm: E. Other Related Work—such labels for petroleum prod- <br /> The contractor shall provide as Excavation and Boiler ucts shall be affixed to <br /> double-wall Fiberglas under- Equipment each tank. <br /> ground storage tanks U.L. <br /> labeled for petroleum products 1,02 Quality Assurance D. Installation Instructions: <br /> in sizes and with fittings as A. Acceptable Manufacturers: Contractors shall submit <br /> shown on the drawings. The O/C TANKS Corporation, _copies of manufac- <br /> tanks shall be manufactured Toledo, Ohio turer's latest installation <br /> by O/C TANKS. instructions. <br /> Tanks shall be tested and B. Governing Standards: <br /> 1. ASTM Specification D4021- E. Calibration Charts: Con. <br /> installed with pea gravel or 86. Glass Fiber Reinforced tractors shall submit_ <br /> approved alternate backfill Polyester Underground copies of manufacturer's <br /> material according to the Petroleum Storage Tanks. latest calibration charts. <br /> current installation instructions 2. U.L. 1316. Underwriters <br /> (O/C TANKS publication 3-PE- Laboratories, Inc., Glass <br /> 6304) provided with the tank. Fiber Reinforced Plastic <br /> Underground Storage <br /> Tanks for Petroleum <br /> Products. <br /> 3. National Fire Protection <br /> ASSOC. (NFPA 30) Flam- <br /> mable and Combustible <br /> Liquids Code and (NFPA <br /> 31)Standards for Installation <br /> of Oil Burning Equipment. <br /> 4. National Sanitation Foun- <br /> dation Testing Laboratory, <br /> January 1984, listing of <br /> Plastic Piping System <br /> Components and Related <br /> Materials, Standard 15. <br /> 5. Military Specification <br /> MIL-T-52777A, dated July 6, <br /> 1978,Tanks,Storage, Under- <br /> ground, Glass Fiber Rein- <br /> forced Plastic. <br /> 6. General Services Adminis- <br /> tration, Public Building <br /> Service Guide Specification, <br /> PBS: 1568. <br /> i <br /> 28 <br />