My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
INSTALL_1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:53:13 AM
Creation date
11/8/2018 9:39:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\INSTALL 1992.PDF
QuestysFileName
INSTALL 1992
QuestysRecordDate
8/2/2017 4:00:35 PM
QuestysRecordID
3544491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ii SKr r .LCTj <br /> Part II Products• C. Dimensional Requirements 5. The double-wall tank <br /> 2.01 Double-Wall Fiberglas® (refer to O/C TANKS litera- monitor shall be capable <br /> Underground Storage Tanks ture on gallonage): of detecting a breach in <br /> A. Loading Conditions Tank 1. Nominal capacity of the the inner and/or outer <br /> shall meet the following tank shall be—gallons. tank under the following <br /> design criteria: 2. Nominal outside diameter installed conditions: <br /> 1. External hydrostatic pres- of the tanks shallbe_feet. a. When the inner tank <br /> sure. Buried in ground with 3. Nominal overall length of is empty. <br /> 7'of overburden over the the tanks shall befeet. b. When the inner tank is <br /> top of the tank, the hole partially or completely <br /> fully flooded and a safety D. Monitoring Capabilities: full and the groundwater <br /> factor of 5:1 against general 1. Tanks shall have a space table is below the tank <br /> buckling. between the primary and bottom. <br /> 2. Surface loads: When secondary shell walls to c. When the inner tank is <br /> installed according to manu- allow for the free flow and partially or completely <br /> facturer's installation instruc- containment of all leaked full and the tank is par- <br /> tions tanks will withstand product from the primary tially or completely sub- <br /> surface H-20 axle loads tank. merged in groundwater. <br /> (32,000 lbs./axle). 2. The following continuous 6. The leak detection perfor- <br /> 3. Internal load: Primary and monitoring conditions shall mance of the monitoring <br /> secondary tanks shall with- be compatible with the system shall be tested <br /> stand 5 psi air pressure test cavity between the inner and verified by a qualified <br /> with 5:1 safety factor. and outer tanks: independent consultant to <br /> 4. Tanks shall be designed to • Vented to atmosphere detect leaks as small as <br /> support accessory equip- • Sealed tank cavity 0.05 gallons per hour with a <br /> ment such as heating coils, • Vacuum-3" mercury 95% probability of detection <br /> ladders, drop tubes, etc. maximum (1.5 psi and less than a 5% proba- <br /> when installed according to maximum) bility of a false alarm. <br /> manufacturer's recommen- • Positive air pressure 7. All monitoring equipment, <br /> dations and limitations. (3 psi maximum) including FRP reservoirs <br /> • Hydrostatic pressure— and electronic control shall <br /> B. Product Storage 7 foot maximum ground- be U.L. listed. <br /> Requirements: water head pressure over 8. If hydrostatically monitored, <br /> 1. All primary tanks must be tank top. any solution used in the <br /> vented. Tanks are designed 3. Tanks shall have an tank annular space shall <br /> for operation at atmospheric integrally-mounted reser- have U.L. approval for <br /> pressure only, except for voir installed on the tank for compatibility with the tank. <br /> use with vapor recovery optional hydrostatic moni- <br /> systems at a pressure or toring. The reservoir shall <br /> vacuum of approximately be constructed of fiberglass <br /> 1 psi. reinforced plastic materials <br /> 2. Tanks shall be capable of and warranted for 30 years <br /> storing liquids with specific against failure due to <br /> gravity up to 1.1. internal/external corrosion <br /> 3. Maximum temperature: and,when properly installed, <br /> Tank shall be capable of against structural failure <br /> storing gasoline, alcohol (same as tank warranty). <br /> blended gasoline (with 4. Tank shall be designed with <br /> up to 100% methanol or access to the tank bottom <br /> ethanol), oxygenated fuels between the primary and <br /> (up to 20% MTBE), av-gas, secondary walls (annular <br /> jet fuel, motor oil (new or space). All tanks shall have <br /> used), kerosene, diesel fuel one 4" NPT monitoring fit- <br /> or potable water at ambient ting in the reservoir(6" NPT <br /> underground temperatures for 10'diameter tanks).Tanks <br /> not to exceed 150°F at the 4,000 gallon capacity and <br /> tank interior surface. larger shall also have one <br /> 4. Tanks shall be chemically additional 4" NPT monitor- <br /> inert to petroleum products. ing fitting. <br />