INSTALL 2018 PLAN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2019 4:47:15 PM
Creation date
11/8/2018 9:40:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018 PLAN
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
MANTECA CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL PLAN.PDF
QuestysFileName
2018 INSTALL PLAN
QuestysRecordDate
5/2/2018 6:46:32 PM
QuestysRecordID
3878440
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRESSURE VACUUM VENT <br /> UP FLOW VENT CAP(DO NOT PAINT) *) <br /> (DO NOT PAINT) <br /> 12' MIN. <br /> 12' MIN. <br /> WHIP HOSE <br /> 3"DIESEL <br /> VENT RISER <br /> .. <br /> HOSE BREAKAWAY SPEAKER 2"GALVANIZED archin tecr tu <br /> e n g i e e i n rg e <br /> THE 3 FOOT RADIUS SPHERE IS CLASSIFIED TEE <br /> ELECTRONIC <br /> HOSE PAYMENT READER AS CLASS I, DIVISION 1, GROUP D L+-B & Associates, Ltd. <br /> DISPENSER /KEYPAD <br /> THE 5 FOOT RADIUS SPHERE IS CLASSIFIED 867 Pacific Street,Suite 120 <br /> DISPLAY SCREEN-----.— SENSOR HOUSING VALVE ENCLOSURE AS CLASS I, DIVISION 2, GROUP D San Luis Obispo,CA 93401 <br /> RECEIPT ASSEMBLY TO TEMP ph 805.540.5240 <br /> fax 805.540.5241 <br /> SENSOR www.LHBassoc.com <br /> DISPENSER / j —�\ \ <br /> — — — — — — — — — — LIFTING 12'MIN <br /> HOOKS <br /> LU ® AS <br /> SEMBLV FILTER TO TLS <br /> Eq Z DISPENSER o 0 0 0 ° VENT RISER <br /> DO NOZZLE 00 L71 SUPPORT B `FG <br /> w Q MOUNTING / / —�--� \. RACK ~ Q� <br /> _T BRACKET <br /> L) MULTI PLANE v ASSEMBLY <br /> a W SWIVEL — 00 n \ \ \ \ y O_ <br /> U _ z / 3"SCH. 40 STEEL m <br /> p� f— <br /> 8"SECTION OF UNISTRUT PIPE COLUMN NO.7$916 A fATI <br /> 00 Uj 0 0 `1 P1001 CHANNEL WITH(1) / / IY 03/1$ <br /> — - - - - - - - - - - - — M Of <br /> W : f CLAMP558- 0 8 W P2558-30LOCATIONS)PIPE I I \ I I It 9 e <br /> D'' W = 110„MIN CLAMPS(TWO LOCATIONS) <br /> Z DISPENSER U) <br /> PEDESTAL TF OF CA��FO� <br /> DISPENSER BASE 121/2" <br /> CANISTER 2"THREADED <br /> ASSEMBLY VENT PIPE \ \ CONSULTANTS <br /> NOTES: 2"SCH. 40 GALV. <br /> 1. DISPENSERS SHOWN HAVE ATOP HOSE MOUNT. NLET PIPING KIT REDO IN STEEL VENT RISER <br /> 2. MAXIMUM HEIGHT OF OPERABLE CONTROLS LOCATED ON FREE STANDING REDUCING TEE \ \ PAINT TO MATCH SITE <br /> PEDESTAL IS 48" FORA 10" MAX. REACH DEPT FRONT SIDE RIGHT SIDE REAR SIDE LEFT SIDE CONDITIONS <br /> 3. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT \ \ <br /> REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE 1 / / e c <br /> FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS <br /> (22.2N) MAXIMUMit I. <br /> 8 DISPENSER ELEVATION (1 +1 ) 6 VEEDER-ROOT CARBON CANISTER DETAILS OLASSIFIED AREA <br /> ((1 +0) ELEVATION SIMILAR) SCALE:N.T.S. <br /> SCALE: N.T.S. <br /> ESIGN CRITERIA <br /> J� OHO 1D. MIN CONC COMP STRENGTH 3ksi <br /> 12` Jw�P J� 2. MIN SOIL LAT BRIG STRENGTH 0.27ksf <br /> 2"DOUBLE WALL 12„ Q0�\ VENT RISER DETAIL <br /> FRP PIPE (TYP) 12„ <br /> `� SCALE. 1/2"=1'-0" REVISIONS <br /> `0�� t1`e PLAN CHECK#16-3684 <br /> 6" fill 5J OVERFILL 07 DECEMBER 2016 <br /> ALARM 2"TEE W/114"TEST PORT FITTING L2 ENGINEERING PLAN CHECK <br /> Ml N 2 #16-3684,3685 29 MARCH 2016 <br /> 1/2"MIN. BETWEEN 6" AND 1/4" PLUG (TYP.) <br /> FITTINGS (TYP.) MIN EMERGENCY SHUT-OFF SWITCH IN 2 2' " #SJC SR EHD PLAN CHECK8NOVEMR.2017 <br /> 6" WATERPROOF ENCLOSURE 3 <br /> MIN 6'0 PIPE BOLLARD ALARM <br /> KNOWLEDGE 2-IN-1 SENSOR BOX <br /> WITH CONCRETE <br /> FILL, (TYP.OF SWITCH <br /> -PAINT TO MATCH ALUMINUM DIAMOND <br /> SITE CONDITIONS PLATE LID <br /> o I O <br /> O EXPLOSION PROOF SUBMITTAL DATES <br /> TIGHTF ID JUNCTION BOX <br /> TIGHT FLEX <br /> 3 OWNER: <br /> 14'x1PLAT" MINI HYDROSTATIC SUMP <br /> VAPOR VENT BOX 03/29/2016 <br /> STEEL PLATE 4N4"NEMA ® RACK SYSTEM REG. AGENCIES <br /> PAINT TO 3R JUNCTION BOX ANNULAR SENSOR W/BRINE <br /> NOTES: a E <br /> SI CONTIONS <br /> RESERVOIR AND SIGHT GLASS <br /> ALL VAPOR RECOVERY CROSS OVER PIPING TO BE MADE � (T.�,P ) -- <br /> RECEPTACLEPTACLE O.T.B.: <br /> WITH TEE(OR 90° ELL), SHORT NIPPLE AND 45° ELL. a/4°acs <br /> W'x4"STEEL CONDUIT 3/4"FIBERGLASS CUFF 2"x18"FxMS FLEX <br /> SLOPE PRODUCT PIPING TOWARD UNDERGROUND FUEL POST,PAINT TO ENTRY CONNECTOR MATCH SITE sEAwFF <br /> CONDITIONS 3 II <br /> STORAGE TANKS OR DISPENSER SUMP AT 1/8" PER FOOT PIPING (TYP.) SENSOR 15-13-001 <br /> MINIMUM. PROJECT NO, <br /> 3"OVER 2"D.W. I MOUNTING KIT DRAWN BY: <br /> UNLEADED TANK. I <br /> VAPOR RECOVERY LINES TO SLOPE 1/8"/FT. TO REGULAR FINISH GRADE FRP VENT PIPING Qm 2"90° ELBOW <br /> AFS <br /> �{ CHECKED BY: <br /> ° �° <br /> PRODUCT LINES AND DISPENSER CONNECTIONS MAY G 2"FRP BELL x MALE <br /> 4 <br /> NOT BE IN SAME ALLIGNMENT. USE FLEXIBLE 3 O FIBERGLASS D.W. ADAPTER JRB <br /> CONNECTORS AND ROTATE TEES (OR ELBOWS) LEFT OR LIQUID SENSOR <br /> RIGHT OF VERTICAL AS NECESSARY TO MAKE CUFF ENTRY <br /> — <br /> CONNECTIONS. 2"FRP TERMINATION FITTING 3 NON-DISCRIMINATING <br /> ITH TEST PORT AND VACUUM <br /> 3/4"RGS PVC DOUBLE WALL VENT LINE <br /> CAOTEDCONDUIT 'IDC CONCRETE <br /> (TYPJ TUBING ROUTED TO VAC TRANSITION SUMP <br /> SENSOR ASSEMBLY <br /> ALTERNATE LOCATION:MOUNT TO VENT 10 ROS TRANSITION <br /> RACK. <br /> fh <br /> DO <br /> PIPING CROSSOVER DETAIL (c� UNDER DISPENSER SUMP 4 VEEDER-ROOT OVERFILL ALARM SWITCH //��\ VENT LINE TERMINATION SUMP = Q � Q <br /> SCALE:N.T.S. <br /> SCALE: 1/2"-1'-0" G SCALE: 1"=1'-0" U Z <br /> Z <br /> UP FLOW VENT W O <br /> PRESSURE/VACUUM Q <br /> (DIESEL) VALVE L J <br /> MANIFOLD Z I— U <br /> Q ULU <br /> " <br /> 2"NOMINAL 1:71o Z <br /> I— <br /> ID MIN. Q <br /> CONCRETE SLAB <br /> 2"NOMINAL FILL PIPE WITH CONCRETE 3/4"TRACER TIGHT HORIZONTAL <br /> D MIN, ASPHALT PAVING SAMPLING PROBE <br /> p� BASE MATERIAL -CENTER OVER PIPING <br /> 5L� <br /> 6"0 SCH 80 STEEL PIPE BUMPER 3"OVER 2" FRP PRODUCT <br /> POST PIPING <br /> VAPOR <br /> -CENTERLINE FOOTING <br /> 2" RETURN -PAINT WHITE d <br /> a <br /> 3° LINES <br /> i W m SHEET TITLE <br /> N <br /> ? A.C. PAVING OR CONCRETE SLAB 01 Z > } "" <br /> a d m <br /> O z JU 9 <br /> p Gl U u . io > <br /> 0 <br /> r <br /> � fuer <br /> s�opF RFCG o7Fs�l e� ® ® 3 FUELING <br /> EXPANSION JOINT co — W PEA GRAVEL N DETAILS <br /> 2., <br /> �RFLi7 CONCRETE FOOTING o] m <br /> =3 r o <br /> ✓, rt _t.}i r'x'ti� n,.,r k.„s,t,�' m <br /> DOUBLE WALL FRP <br /> VEHICLE IMPACT PROTECTION: VAPOR LINE �`J <br /> 1. GUARD POSTS SHALL BE SPACED NOT 6 1/2" 6 112" 6 1/2" 6 1/2" 6 1/2" PIPING <br /> 2% <br /> MORE THAN 4 FEET BETWEEN POSTS MIN. * * `o <br /> ON CENTER. 101, * 0 <br /> S O 2. GUARD POSTS SHALL BE LOCATED NOT MAX CLEAR o <br /> �. LESS THAN 4 FEET FROM PROTECTED <br /> OBJECT. NOTES <br /> U <br /> 1. USE PIPE MANUFACTURER RECOMMENDED SUPPORTS EVERY v SHEET NO. <br /> 8'-0" (FOR RIGID F.G. PIPING ONLY) <br /> 2. SPACING FOR FLEXIBLE PIPING TO BE 2x PIPE DIAMETER. <br /> ,� O TYPICAL STAGE II PIPING 7 BOLLARD DETAIL <br /> SCALE: N.T.S. SCALE: N.T.S. <br /> 5 DISPENSER ACCESSIBILITY PIPE TRENCH DETAIL FS-7 <br /> SCALE: N.T.S. J SCALE: 1/4"=1'-0" M <br /> N <br /> I7 <br />