M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:18 PM
Creation date
11/8/2018 9:41:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
CENTRAL GAS STOCKTON
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\3440\PR0231173\COMPLIANCE INFO 2013 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certir'uation <br /> D. Results of Testing/Servicing, RECEIVED <br /> Software version hisralled: 329.01 JUL 31 2014 <br /> Complete tate followin checklist; <br /> Yes j ,❑ No` Is the audible alarm operational? TH <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> J ® Yes ❑ No'— Were all sensors visually inspected,Nnctionatly tested,and confirmed operational? <br /> Yes p No* Were all seuso:f installed et:Qwest point of secondary conlainment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> Q Yes ❑ No, If alarms are relayed to a remote monitoring station, is all cornmunications equipment (c.&, modem) <br /> N/A operational? <br /> ® Yes [] No* For pressurized piping systems,does the turbine autornatically shut down if the piping secondary ccma.n' ment it <br /> ❑ N/A monitoring system detects a Ieak,fail$to operate, or is electrically disconnected? If yes: .vhicb sensors initiate <br /> 1 positive shut-down? (C'hack all that apply) ® Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confcu7a positive shut-down due to Icaks and Itellsor failureldisconnection? 0 Yes; ❑ No. <br /> ❑ Yes 0 No* For tank systems `hat utilize the monitoring system as the primary tank overfill warring device (i e., no !i <br /> E N/A mechanical uverfill prevention valve is installed), is the overfill wanting aiarrn visible and audible at the tank <br /> fill point(s)and operating properly? ]f so,at what percent of tank capacity does the alarm trigger!? 90% <br /> Yes* 1Z No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list Mie manufacturer name and model for all replacemen.,parts in Section!;,below. <br /> Cl Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑ Water- If yes,describe causes in Section L,below. <br /> ® Yes ❑ Tiro" Was monitoring system set-up reviewed to ensure proper settings?Attack set up reports,if applicable <br /> ® Yes ❑ No" Ts all monitoring equipment operational por manutacturer's specifications? <br /> ' In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Page 2 of 4 <br /> C'd wneloaled elclelle-d eZ 6:90 V 1 l,C Inr <br />
The URL can be used to link to this page
Your browser does not support the video tag.