Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> i TaMmo%gy <br /> TEST DATE:12/16/99 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2210724 <br /> CLIENT:ULTRAM&R INC AUSTIN,TEXAS 78757(512)451-6334 SITE:ULTRAMAR 492 <br /> TANK INFORMATION ET,,..lu <br /> Tank ID: 87 1 Tank manifolded: NO Bottom to top fill in inches: 134.o <br /> Product: UNLEADED Vent manifolded: YES <br /> Bottom to grade in inches: 141.o <br /> Capacity in gallons: 14,130 Vapor recovery manifolded: YES Fill pipe length in inches: 38.0 <br /> Diameter in inches: 96.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 337 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: Dw STEEL Installed: ATG Stage If vapor recovery: AssxsT <br /> CP installed on: <br /> COMMENTS <br /> ,SANI(TEST:RESUL?$:rest Methotl:'VecuTact' <br /> LEAK DETECTOR TEST'RESULTS7 "Test.trtethod,-' *:- <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced Newipassed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: Fx <br /> Test time: S/N: 409987659 <br /> Inclinometer reading: Open time in sec: 4.00 <br /> Holding psi: 11 <br /> VacuTect Test Type: NOT Resiliency cc: 135 NOT <br /> VacuTect Probe Entry Point: TESTED <br /> Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> ,;,t; `'k kepp LINE i�EST RCSl7LI'S ay �,, t,: Testt pe TLD 39'; <br /> rYw``w,aas``s' � LI : ,. A ... . -- - <br /> IN <br /> Material: DW FIEERG <br /> Diameter(in): 2.0 <br /> Length (ft): 40.0 <br /> Test psi: 50 <br /> Bleedback cc: 65 <br /> Test time (min): 30 NOT NOT NOT <br /> Start time: 09:45 TESTED TESTED TESTED <br /> End time: 10:15 <br /> Final gph: 0.006 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Draft 12/17/1999 13:42 MSHAW <br />