My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • Page_of <br /> 6. SUBMERSIBLE PUMP CONTAINMENT SUMP TESTING <br /> Test Method Developed By: X Sump Manufacturer Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Uses: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Measuring Equipment tlsed for Testing: UST 2000P <br /> J� Sump#1 RU Sump#2 SU Sump#SU <br /> Sump Diameter: 42" 42" <br /> Sump Depth: <br /> 44" 42" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Highest 14„ 15" <br /> Piping Penetration: <br /> Height from Tank Top to Lowest 18„ 21" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: FAIR FAIR <br /> Portion of Sump Tested' 2"ABOVE PRODUCT 2"ABOVE PRODUCT <br /> PENETRATION PENETRATION <br /> Wait time between applying 15MIN 15MIN <br /> ressure/vacuun✓water and startin test: <br /> Test Start Time: 0746 0815 <br /> Initial Reading(Rt): .5712 .0390 <br /> Test End Time: 0758 0827 <br /> Final Reading(RF): .5700 .0388 <br /> Test Duration: 12MIN 12MIN <br /> Change in Reading(RF-Ri): -.0012 -.0002 <br /> Pass/Fail Threshold: +/-.002" +/-.002" <br /> Test Result: PASS PASS <br /> Was sensor removed for testing? YES YES <br /> Was sensor properly replaced after YES YES <br /> testing? <br /> Comments (include information on repairs made prior to testing) <br /> SWRCB December 2001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.