My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDOW TANK INFORMATION AND EST RESULTS <br /> s-i Tankno/ogy <br /> 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER: 2220097 <br /> TEST DATE: 12/27/01 AUSTIN,TEXAS 78757(512)451-6334 <br /> CLIENT: ULTRAMAR INC SITE: UI,TRAMAR 492 <br /> „. _ <br /> . <br /> Tank ID: 92 2 Tank manifolded: xo Bottom to top fill in inches: 133.0 <br /> Product: SUPER Vent manifolded: yEs Bottom to grade in inches: 141.0 <br /> Capacity in gallons: 1,410 Vapor recovery manifolded:yEs Fill pipe length in inches: 37.0 <br /> Diameter in inches: 96.00 Overfill protection:yES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 344 Overspill protection:yEs Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> ewe hQt! L o z i ,iWAW. <br /> PSI at tank bottom. fr New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: RED JACKET <br /> Fluid volume in gallons: Model: Fxiv <br /> Tank water level in inches: S/N: 409997659 <br /> Test time: NOT Open time in sec: 3.00 <br /> Number of thermisters: TESTED Holding psi: 16 NOT <br /> Specific gravity: Resiliency cc: 110 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> ULLAGE TEST RESULT STest Methp , UNE ",g " '' „8��,^✓; �', ._ .c"': \<;, <br /> Test time: Material DW FIBERG <br /> Ullage volume: Diameter(in): 2.0 <br /> Length (ft): 40.0 <br /> Ullage pressure: Test psi: <br /> Results: Bleedback cc: <br /> Test time(min): <br /> DATA FOR UTS-4T ONLY: Test 1:Start time: <br /> Time of test 1: Finish psi: NOT NOT NOT NOT <br /> Tem erature: NOT Vol change cc: <br /> Test 2: Start time: TESTED TESTED TESTED TESTED <br /> P <br /> Flow rate(cfh): TESTED Finish psi: <br /> Time of test 2: Vol change cc: <br /> Test 3:Start time: <br /> Temperature: Finish psi: <br /> Flow rate(cfh): Vol change cc: <br /> Time of test 3: Final gph: <br /> Temperature: Result: <br /> Flow rate(cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational:UNKNowN <br /> Printed 0110712002 13:15 CCHAPA <br />
The URL can be used to link to this page
Your browser does not support the video tag.