Laserfiche WebLink
Executive Order VR-101-D, Phil-Tite Phase I Vapor Recovery System, Exhibit 2, Page 2 <br /> an equivalent material that has been listed for use with gasoline. If a material other than <br /> steel is used, the GDF operator shall make available information demonstrating that the <br /> material is compatible for use with gasoline. One example of a typical vent pipe manifold is <br /> shown in Figure 2F. This shows only one typical configuration; other manifold configurations <br /> may be used. For example, a tee may be located in a different position, or fewer pipes may <br /> be connected, or more than one PN valve may be installed on the manifold. <br /> 4. The vent pipe manifold shall be installed at a height not less than 12 feet above the grade <br /> used for gasoline cargo tank delivery operations and shall conform to all applicable <br /> regulations. <br /> 5. Each PN valve shall have permanently affixed to it a yellow or gold-colored label with <br /> black lettering stating the following specifications: <br /> Positive pressure setting: 3.0± 0.5 inches H2O <br /> Negative pressure setting: -8.0± 2.0 inches H2O <br /> Positive Leakrate: 0.05 CFH at 2.0 inches H2O <br /> Negative Leakrate: 0.21 CFH at-4.0 inches H2O <br /> Rotatable Product and Vapor Recovery Adaptors <br /> 1. Rotatable product and vapor recovery adaptors shall be capable of at least 360-degree <br /> rotation and have an average static torque not to exceed 108 pound-inch (9 pound-foot). <br /> Compliance with this requirement shall be demonstrated in accordance with the latest <br /> adopted version of TP-201.1 B, Static Torque of Rotatable Phase 1 Adaptors. <br /> 2. The vapor adaptor poppet shall not leak when closed. Compliance with this requirement <br /> may be verified by the use of commercial liquid leak detection solution, or by bagging, <br /> when the vapor containment space of the underground storage tank is subjected to a non- <br /> zero gauge pressure. (Note: leak detection solution will detect leaks only when positive <br /> gauge pressure exists.) <br /> Vapor Recovery and Product Adaptor Dust Caps <br /> Dust caps with intact gaskets shall be installed on all Phase I tank adaptors. <br /> Spill Container Drain Valve <br /> The spill container drain valve is configured to drain liquid directly into the drop tube and is <br /> isolated from the underground storage tank ullage space. The leak rate of the drain valve shall <br /> not exceed 0.17 CFH at 2.00 inches H2O. Depending on the presence of the drop tube overfill <br /> prevention device, compliance with this requirement shall be demonstrated in accordance with <br /> the latest adopted version of either TP-201.1 C, Leak Rate of Drop Tube Overfill Prevention <br /> Device and Spill Container Drain Valve; or TP-201.1 D, Leak Rafe of Drop Tube/Drain Valve <br /> Assembly. <br /> Drop Tube Overfill Prevention Device <br /> 1. The Drop Tube Overfill Prevention Device (overfill device) is designed to restrict the flow of <br /> gasoline delivered to the underground storage when liquid levels exceed a specified <br />