My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Executive Order VR-101-D Phil-Tite Phase I Vapor Recovery System <br /> Exhibit 3 <br /> Manufacturing Performance Standards and Specifications <br /> The Phil-Tite system and all components shall be manufactured in compliance with the <br /> performance standards and specifications in CP-201, as well as the requirements specified in <br /> this Executive Order. All components shall be manufactured as certified; no change to the <br /> equipment, parts, design, materials or manufacturing process shall be made unless approved in <br /> writing by the Executive Officer. Unless specified in Exhibit 2 or in the ARB approved <br /> Installation, Operation and Maintenance Manual for the Phil-Tite Phase I Vapor Recovery <br /> System, the requirements of this section apply to the manufacturing process and are not <br /> appropriate for determining the compliance status of a GDF. <br /> Pressure/Vacuum Vent Valves for Storage Tank Vent Pipes <br /> 1. Each PressureNacuum Vent Valve (PN valve)shall be 100 percent performance tested at <br /> the factory for cracking pressure and leak rate at each specified pressure setting and shall <br /> be done in accordance with TP-201.1 E, Leak Rafe and Cracking Pressure of <br /> PressureNacuum Vent Valves. Each PN valve shall be shipped with an card or label <br /> stating the performance specifications listed below, and a statement that the valve was <br /> tested to, and met, these specifications. <br /> a. The pressure settings for the PN valve <br /> Positive pressure setting of 3.0 ± 0.5 inches H2O. <br /> Negative pressure setting of-8.0± 2.0 inches H2O. <br /> b. The leak rate for each PN valve, including connections, shall not exceed: <br /> 0.05 CFH at 2.0 inches H2O. <br /> 0.21 CFH at-4.0 inches H20- <br /> 2. Each PN valve shall have permanently affixed to it a yellow or gold label with black <br /> lettering listing the positive and negative pressure settings specified above. The lettering of <br /> the label shall have a minimum font size of 20. <br /> Rotatable Product and Vapor Recovery Adaptors <br /> 1. The rotatable product and vapor recovery adaptors shall not leak. <br /> 2. The product adaptor cam and groove shall be manufactured in accordance with the cam <br /> and groove specifications shown in Figure 3A of CP-201. <br /> 3. The vapor recovery adaptor cam and groove shall be manufactured in accordance with the <br /> cam and groove specifications shown in Figure 3B of CP-201. <br /> 4. Each product and vapor recovery adaptor shall be 100 percent performance tested at the <br /> factory for static torque, rotatability, and the absence of liquid or vapor leaks. Each <br /> adaptor shall have affixed to it a card or label stating the performance specification listed <br /> below, and a statement that the adaptor was factory tested to, and met, the following <br /> specifications: <br />
The URL can be used to link to this page
Your browser does not support the video tag.