My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Executive Order VR-101-D, Phil-Tite Phase I Vapor Recovery System, Exhibit 3, Page 2 <br /> a. The average static torque for the rotatable adaptor shall not exceed 108 pound-inch <br /> average static torque when tested in accordance with the latest adopted version of <br /> TP-201.113, Static Torque of Rotatable Phase 1 Adaptors. <br /> b. The rotatable adaptor shall be capable of rotating at least 360 degrees when tested <br /> in accordance with the latest adopted version of TP-201.1 B, Static Torque of <br /> Rotatable Phase I Adaptors. <br /> Spill Container and Drain Valves <br /> Each Spill Container Drain Valve shall be 100 percent performance tested at the factory. Each <br /> Spill Container Drain Valve shall have affixed to it a card or label stating the performance <br /> specifications listed below, and a statement that the valve was tested to, and met, the following <br /> performance specification; <br /> a. The maximum leak rate shall not exceed 0.17 CFH at 2.00 inches H2O when tested in <br /> accordance with the latest adopted version of either TP-201.1 C, Leak Rate of Drop <br /> Tube/Drain Valve or TP-201.1 D, Leak Rate of Drop Tube Overfill Prevention Device. <br /> Drop Tube Overfill Prevention Device <br /> Each Drop Tube Overfill Prevention Device shall be 100 percent performance tested at the <br /> factory to verify that it does not exceed the maximum allowable leak rate. Each Drop Tube <br /> Overfill Prevention Device shall have affixed to it a card or label stating the performance <br /> specifications listed below, and a statement that the device was tested to, and met, the following <br /> performance specification; <br /> a. The maximum leak rate shall not exceed 0.17 CFH at 2.00 inches H2O when tested in <br /> accordance with the latest adopted version of TP-201.1 D, Leak Rate of Drop Tube <br /> Overfill Prevention Device. <br /> Table 3-1 <br /> Manufacturing Component Standards and Specifications <br /> Component Test Method Standard or Specification <br /> Minimum, 360-degree rotation <br /> Rotatable Phase I Adaptors TP-201.16 Maximum, 108 pound-inch average <br /> static torque <br /> Rotatable Phase I Adaptors Micrometer Cam and Groove Specifications <br /> (CP-201) <br /> Overfill Prevention Device TP-201.1D <0.17 CFH at 2.00 inches H2O <br /> Spill Container Drain Valve TP-201.1C or <0.17 CFH at 2.00 inches H2O <br /> TP-201.1D <br /> Positive Pressure: 3.0 ±0.5 inches H2O <br /> Pressure/Vacuum Vent Valve TP-201.1E Negative Pressure: -8.0±2.0 inches H2O <br /> Leak rate: <_ 0.05 CFH at +2.0 inches H2O <br /> < 0.21 CFH at-4.0 inches H2O <br />