COMPLIANCE INFO 2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:36:29 PM
Creation date
11/8/2018 9:42:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
4/6/2018 9:22:04 PM
QuestysRecordID
3847503
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
252
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Designated Underground Storage Tank (UST) Operator <br /> Monthly Visual Inspection Checklist <br /> Facility Name:ConocoPhilli s Site#2705445 1 Date:3/21//06 <br /> Facility Address: 1206 E.March Lane <br /> City: Stockton Zip Code: 95210 <br /> Designated UST Operator Conducting the Inspection:Julie Lee <br /> International Code Council Certification#: 5248777-UC Expiration Date: 12/14/2006 <br /> Signature: <br /> Phone: (510)245-5218 <br /> �°` <br /> Y=Yes,N=No, A=NotAppllcable <br /> Item MONITORING PANEL/ALARM HISTORY Y N NA <br /> 1 Monitoring system is powered on and in proper operating mode. x <br /> 2 Monitoring system is not currently showing any alarms or warnings. x <br /> 3 Alarm history report/log for the previous month is available,and has been reviewed by the x <br /> Designated UST Operator. (Attach a copy of the alarm history report/logreport/log to thisform i available) <br /> 4 Each alarm for the previous month has been responded to appropriately. x <br /> 5 Sensors located in tank-top containment sums have not alarmed in the past month. x <br /> 5a List all tank-top sumps where alarms occurred in the past month: <br /> N/A <br /> Note:Sumps where an alarm has occurred in the past month must be inspected unless a qualified service technician responded to,and <br /> properly addressed, the cause oJlhe alarm.Attach documentation verifying appropriate service to this report <br /> If sump inspection is req aired,record results in item 6,below. <br /> UST SYSTEM INSPECTION <br /> 6 Tank-top containment sumps are free of water,debris,and hazardous substance. Sensors are located properly. <br /> Nole:Visual inspection o sums is only required in sum s where an alarm has occurred in thepast month or which there is no service record. <br /> Y N Y 1properly.Sum Location: Sum Location: <br /> Sum Location: Sum Location: <br /> Sum Location: Sum Location: <br /> 7 Spill containment structures are free of water,debris,and hazardous substance. <br /> Y N NA YTank 1 —Contents: 87 x Tank 3—Contents:91 x <br /> Tank 2—Contents:Diesel x Tank 4—Contents: <br /> 8 Under-dis enser containment areas are free of water,debris, and hazardous substance. Sensors are located <br /> Y N NA Y N NA <br /> Dispenser 112 x Dispenser 7/8 x <br /> Dispenser 3/4 x Dispenser 9/10 x <br /> Dispenser S x Dispenser 13/14 <br /> Dispenser G x Dis enser 15 116 <br /> PAPERWORK INSPECTION Y N NA DATE DONE <br /> 9 Monitoring system certification has been completed within past 12 months. x 5/12/05 <br /> 10 Secondary containment tests have been completed within the required timeframe. x 12/29/04 <br /> 11 Spill containment structure bucket testing was completed within the past year. x 5/12/05 <br /> 12 Tank tightness testing was completed within required timeframe. x <br /> 13 Line tightness testing was completed within required timeframe. x <br /> 14 Other required testing/maintenance was completed within required timeframe. (List test/maintenance items below.) <br /> Test/Maintenance: <br /> Test/Maintenance: <br /> Test/Maintenance. <br /> _. ... <br /> FACILITY EMPLOYEE TRAINING YV NA <br /> 15 All facilityemployees have received the required on-the-job trainingwithin the past year. x <br /> 16 All facilityemployees hired within the past 30 days have received the required on-the-job training. x <br /> Note: Any answer of should be explained in the comment section on the following page,and will require <br /> follow-up action. <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.