Laserfiche WebLink
MONITARING SYSTEM CERTIFITION <br /> Use By All Jurisdictions Within the State of Califon' <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16,Division 3 Title 23, c allfomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitonng system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitor np system control oanel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CONOCO PHILLIPS#2705445 City: STOCKTON CA Zip:95210 <br /> Site Address: 1206 E MARCH LANE Contact Phone No: 478-6487 <br /> Date of Testing/Service: 05/05/2006 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:VRTLS350 Work Order Number: 2242520 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> TanklD: 1 TanklD: 2 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 21 Annular Space or Vault Sensor. Model: 407 <br /> -91 Piping Sumprrrench Sensor(s). Model: 205 Piping Sump(Trench Sensor(s). Model: 205 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector, Model: FE PETRO Mechanical Line Leak Detector. Model: FE PETRO <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Madel: <br /> 71 Tank Overfill/High-Level Sensor. Model: MECHANICAL X Tank OverfilitHigh-Leval Sensor. Model: MECHANICAL <br /> Other(specify equipment type and model in Section E on page 2). D Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> X In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: <br /> xj Piping Sump/Trench Sensor(s) Model: 205 Piping SumprTrench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: LD2000 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level Sensor. Model: MECHANICAL Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> X❑Dispenser Containment Sensor(s) Model:206 X Dispenser Containment Sensor(s) Model:205 <br /> TJ Shear Valve(s). :X:j Shear Va[ve(s) <br /> E]Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(# <br /> Dispenser ID: 5 Dispenser ID: 6 <br /> x❑ Dispenser Containment Sensor(s) Model:205 Dispenser Containment Sensor(s). Model:205 <br /> 0 Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 7/B Dispenser ID: 9/10 <br /> ❑X Dispenser Containment Sensor(s) Model:205 X Dispenser Containment Sensor(s) Model:205 <br /> nX Shear Valve(s). X Shear Valve(s} <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): QSystem set-up �Alann history report <br /> Technician Name(print): RAYMOND SIMMS Signature: <br /> Certification No.: 006-05-0282 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 05/05/2006 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />