My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1206
>
2300 - Underground Storage Tank Program
>
PR0231175
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:36:29 PM
Creation date
11/8/2018 9:42:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231175
PE
2361
FACILITY_ID
FA0001247
FACILITY_NAME
DP & DK Investments, Inc.
STREET_NUMBER
1206
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1206 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1206\PR0231175\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
4/6/2018 9:22:04 PM
QuestysRecordID
3847503
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
252
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Onitoring System Certification • <br /> Site Address: 1206 E MARCH LANE Date of Testing/Service: 05/05/2006 <br /> F. In-Tank Gauging / SIR Equipment E] Check this box if tank gauging is used only for inventory control. <br /> Ej Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> Q Yes ❑No' Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> E Yes ❑No` Were all tank gauging probes visually inspected for damage and residue buildup? <br /> 0 Yes ❑No• Was accuracy of system product level readings tested? <br /> Eyes ❑NoWas accuracy of system water level readings tested? <br /> M Yes ❑No' Were all probes reinstalled properly? <br /> Eyes I ON.• Were all items on the equipment manufacturers'maintenance checklist completed? <br /> .In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors (LLD) : ❑ Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? <br /> Q Yes ❑No ON/A (Check all that apply)Simulated leak rate: 0 3 g.p.h O 0.1 g.p.h ❑0.2 g.p.h <br /> x Yes ❑No Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> x Yes ONO' Was the testing apparatus property calibrated? <br /> O Yes E]No` ❑N/A For mechanical LLDs,does the LLD restrict product Now if it detects a leak? <br /> E]Yes ❑NO' ❑x N/A For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> Yes —]No Q N/A For electronic LLDs,does the turbine automatically shut off If any portion of the monitoring system is disabled or disconnected? <br /> E]Yes ❑No• x❑N/A For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br /> O Yes ❑No• Q N/A For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> OX Yes ❑No- Were all items on the equipment manufacturers'maintenance checklist completed? <br /> 'In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> replaced 1 vaporless Id2000 on diesel tank <br /> Page 3 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.