My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 AMENDE <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s'oov.org/ehd I D <br /> Underground Storage Tank Program Ins ed i <br /> Facility Name: Facility Address: Date: <br /> MARCH AND BIANCHI CHEVRON 1916 E MARCH LN STOCKTON November 25 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator did not attach all of the Q and S alarms on the December 2014 through August 2015 <br /> monthly inspection reports. The designated operator also failed to document all the alarms from the attached alarm <br /> history on the December 2014 through March 2015 and September 2015 through November 2015 designated operator <br /> monthly inspection reports and failed to check that they were responded to appropriately. The missing alarms include: <br /> -L2 sensor out alarm on July 20, 2015 <br /> - L12 fuel alarm on September 22, 2015, September 15, 2015 and September 7, 2015 <br /> -L16 fuel alarm on November 9, 2015 <br /> -L19 fuel alarm on February 9, 2015 <br /> -L20 fuel alarm on December 2, 2014 <br /> -L21 fuel alarm on December 23, 2014, December 15, 2014 and December 2, 2014 <br /> -L22 fuel alarm on December 23, 2014 <br /> -L26 fuel alarm on December 13, 2014 <br /> -Q1 gross line fail on November 19, 2015 <br /> -Q2 gross line fail on March 2, 2015 and February 27, 2015 <br /> -Q3 gross line fail on January 2, 2015 and December 5, 2014 <br /> -S5 no vacuum on December 15, 2014 <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class ll. <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training roster was incomplete. The designated operator shall train facility <br /> employees for which he or she is responsible in the proper operation and maintenance of the UST system once every <br /> 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a minor violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): I FATINAH ZAREEF, REHS (209) 953-7311 11/25/2015 <br /> Page 6 of 8 <br />