Laserfiche WebLink
San Joaquin County ���� <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 1 � �_, - ` 7 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www slgov.oro/ehd ----- - `— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MARCH AND BIANCHI CHEVRON 1916 E MARCH LN STOCKTON November 25, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The Diesel sump sensor was raised approximately 2 inches off the lowest point of the sump and not located to detect <br /> a leak at the earliest opportunity. The 87 fill sump sensor was also raised approximately 2 inches off the lowest point <br /> of the sump and not located to detect a leak at the earliest opportunity Monitoring equipment shall be maintained to <br /> be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the lowest point of the sump <br /> by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at the earliest <br /> opportunity. This was corrected on site. <br /> This is a Class II violation. <br /> 320 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion. <br /> Water was found in the: <br /> - Diesel STP sump on east side <br /> -Diesel fill sump on the east and west side <br /> -The 87 fill sump on the east side <br /> -The 91 fill sump on the east side <br /> Secondary containment shall be constructed to prevent any water intrusion into the system by precipitation, <br /> infiltration, or surface runoff. The service technician removed half a gallon of liquid from the diesel STP, diesel fill <br /> sump, 87 fill sump and the 91 fill sump and returned the sensor to its proper location. This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> This is an amended report that supersedes all previously issued reports for this inspection. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 6, 2016 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> NOTES: <br /> -Verified all sensors at lowest point <br /> - Provided RTC <br /> Received by Inspector: Phone: Date: <br /> (initial): FATINAH ZAREEF, REHS (209) 953-7311 11/25/2015 <br /> Page 7 of 8 <br />