My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 1:27:18 PM
Creation date
11/8/2018 9:43:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI CHEVRON
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARCH\1916\PR0527728\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
9/28/2017 8:32:42 PM
QuestysRecordID
3652760
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> D. Results of 7esting/Semicing JAN 14 20:5 <br /> Software Version Installed VR 1.01 EN11YL]OhlMENTf, - <br /> Com ete the followingchecklist: Irl' MVI_.. <br /> X Yes ❑ No- Is the audible alarm operational? <br /> X Yes ❑ No' Is the visual alarm operational? <br /> X Yes No' Were all sensors visually impacted,functionally tested,and confirmed operational? <br /> X Yes = No' Were all sensors installed at lowest point of secondary containment and poskioned so that other equipment will not interfere with their <br /> rimmer o ration? <br /> Yes ❑ NO' If alarms are relayed to a remote monitoring station,Is all communications equipment(e.g.modem)operational? <br /> X WA <br /> X Yes ❑ No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> ❑ WA detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut down? (Check all that apply) <br /> X Sump/Trench Sensors; X Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failureldisconnection? X Yes; No. <br /> X Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention <br /> WA valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? If so,at what percent <br /> of tank capacity does the alarm trigger? 95 % <br /> X Yes• No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> X Yes' No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)❑Product; �❑Water. If <br /> as,describe causes in Section E,below. <br /> X Yes _ No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,i1 applicable <br /> X Yes No' Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: 1 CUP H2O FOUND IN DIESEL STP SUMP, 1.6 GAL DIESEL FOUND IN DISP 11-12 UDC BOTTOM OF 9-10 UDC <br /> WAS WET WITH DIESEL.DIESEL DISP#12 WAS PLACED OUT OF SERVICES FOR REPAIRS. <br /> L2 DISP 1-2 ANNULAR[MIDDLE VR 304 X PASS sensor was in fuel alarm upon arrival sensor was replaced and retested <br /> L4 DISP 3.4 ANNULAR[MODLE VR 304 X PASS <br /> L 6 DISP 5-6 ANNULAR[MIDDLE VR 304 X PASS <br /> L 8 DISP 7-8 ANNULAR[MIDDLE VR 304 X PASS <br /> L 10 DISP 9-10 ANNULAR[MIDDLE VR 304 X PASS <br /> L 12 DISP 11-12 ANNULAR[MODLE VR 304 X PASS <br /> L 13 VENT DOX[MODLE VR 208 X PASS <br /> L 14 VENT BOX ANNULAR[MODLE VR 304 X PASS <br /> L 16 87 STP SUMP ANNULAR[MODEL VR 304 X PASS <br /> L 18 87 FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 20 91 STP SUMP ANNULAR[MIDDLE VR 304 X PASS <br /> L 22 91 FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 24 DIESEL STP SUMP ANNULAR[MODLE VR 304 X PASS <br /> L 26 DIESEL FILL SUMP ANNULAR[MODLE VR 304 X PASS <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.