My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
COMPLIANCE INFO 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/8/2018 9:44:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MARIPOSA\2132\PR0231669\COMPLIANCE INFO\COMPLIANCE INFO 2016.PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/15/2017 6:48:05 PM
QuestysRecordID
3131588
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL 15 2016 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑ Other(Sped) <br /> Test Method Used: ❑Pressure ®Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:Test plugs,venturi pump and gauges Equipment Resolution: 0.5%of span <br /> Tank#87 Tank# 89 Tank# 91 Tank# Diesel <br /> Is Tank Exempt From Testing?' ❑Yes ® No ❑Yes ® No ❑Yes ® No ❑Yes 14 No <br /> Tank Capacity: 12k 12k 12k 12k <br /> Tank Material: Steel Steel Steel Steel <br /> Tank Manufacturer: Modern Welding Modem Welding Modern Welding Modern Welding <br /> Product Stored; Gasoline Gasoline -DieselGasoline <br /> Wait time between applying <br /> pressure/vacuum/water and 10 min. 10 min. 10 min. 10 min, <br /> startin test: <br /> Test Start Time: 8:00 am 8:45 am 10:00 am 12:15 pm <br /> Initial Reading(Rt); 7++h <br /> Test End Time: g 7++hg 7"hg 7"hg <br /> 9:00 am 9:45 am 11:00 am 1:15 pm <br /> Final Reading(Rv): T' <br /> hg 7"hg 7"hg 7"hg <br /> Test Duration: 1 hour 1 hour 1 hour <br /> 1 hour <br /> Change in Reading(RF-RJ; None None None None <br /> Pass/Fail Threshold or Criteria: No detectable loss No detectable loss No detectable loss No detectable loss <br /> Test Result: 191 Pass ❑Fail ® Pass ❑Fail R Pass ❑Fail 181 Pass ❑Fail <br /> Was sensor removed for testing? ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> Was sensor properly replaced and <br /> verified functional atter testing? ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> Comments—(include information on repairs made prior to testing and recommended ollow up for tailed tests) <br /> Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing, fCalifoinia Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.