Laserfiche WebLink
Vacuum Sensor System Installation Guide Vac Sensor Setup <br /> Performing Vac Sensor Setup <br /> After filling in the Vac Sensor Zone Worksheet, enter the Setup Mode and press the FUNCTION key until you see <br /> the message: <br /> SMARTSENSOR SETUP <br /> PRESS<STEP>TO CONTINUE <br /> Press STEP until you see the message: <br /> SS CONFIG-MODULE 1 <br /> SLOT x-X X X X X X X X <br /> Following the completed Vac Sensor Zone Worksheet,configure each Vac Sensor channel for all SmartSensor <br /> modules. NOTE:Once the console communicates with a Vac Sensor(approximately 2 minutes after configuration), <br /> A automatically selects the Vac Sensor SS Category for that sensor. <br /> When all Vac Sensors have been configured, if necessary, press Tank/Sensor until you see the message: <br /> s 1:VAC SENSOR SETUP <br /> PRESS<ENTER> <br /> Press ENTER: <br /> s 1:SELECT PUMP M <br /> NONE <br /> You must select the pump that will provide the source of vacuum for this Vac Sensor or a Setup Data Warning will <br /> be posted for this Vac Sensor. If necessary,press CHANGE until the correct pump's control device displays [QX <br /> (PLLD), WX (WPLLD),or RX (Output Relay)]. NOTE:an Output Relay must be set to Pump Control Output to be <br /> assigned as a pump. If the selected pump output relay is not assigned to a pump sense device,a Setup Data <br /> Warning for this Vac Sensor will be posted. <br /> Press ENTER to confirm your entry. <br /> Press STEP to continue.: <br /> s 1:(Vacuum Label <br /> VOLUME: 501 <br /> Referring to your previously completed volume worksheet,enter the volume in gallons of the interstitial space being <br /> monitored by this Vac Sensor.The permitted range is 0.1 to 500 gallons. Default is 501.A Setup Data Warning <br /> alarm will activate if a volume between 0.1 and 500 is not entered. <br /> Press CHANGE and enter the interstitial space volume. Press ENTER to confirm your entry. <br /> Press STEP to continue.: <br /> s 1: (Vacuum Labet) <br /> RELIEF VALVE: NO <br /> For all Vac Sensors except the one monitoring a fiberglass tank's interstitial space,a relief valve is usually not <br /> needed. For Vac Sensors not requiring a relief valve press STEP to accept the default NO. Press Tank/Sensor to <br /> setup another Vac Sensor. <br /> For the Vac Sensor that monitors a fiberglass tank's interstitial space,a relief valve is required to prevent excess <br /> vacuum from damaging the tank. Press CHANGE and select YES. Press ENTER to confirm your entry. <br /> 22 <br />