Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd, <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY MARKETPLACE 1789 W CHARTER WAY, STOCKTON March 07, 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V o R ❑COS <br /> 323 HSC 25283,5(a) Unburied below grade UST system failed to meet exemption status ❑V o R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V n R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms c V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSG 25298 Failed to comply with permanent closure requirements ❑V o R o COS <br /> 330 CCR 26360(6) Failure to meet afl requirements in lieu of a line leak defector for emergency generator tank system o V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V n R Ej COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984) not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted AdministrationlDocumentation violation ❑V o R o COS <br /> 2030 See below Unlisted Operation slMainto nance violation o V o R n COS <br /> 2060 See below Unlisted DesignlConstruction violation n V n R n COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item#F Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents are more than 365 days old. Current financial responsibility documents are <br /> required to be submitted annually. Financial responsibility documents were uploaded and submitted to CERS at time <br /> of inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan indicated incorrect sensor <br /> models for the UDC sensors, incorrectly marked"Yes,"for"UDC Monitoring Stops Flow of Product at Dispenser", <br /> and also incorrectly marked"Yes,"for"Tank Integrity Testing." The facility manager corrected, and resubmitted to <br /> CERS during the inspection. <br /> This was corrected on site. <br /> This is a minor violation. <br /> FA0007486 PRO506538 SC001 03/07/2017 <br /> EHD 23-01 Rev.09122116 Page 3 of 6 Underground Storage Tank Program OIR <br />