Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazeiton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> [Facility Name: Facility Address: Date. <br /> UNTRY MARKETPLACE 1789 W CHARTER WAY, STOCKTON March 07, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS ll, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double wailed system not maintained. <br /> The 91 annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank is not <br /> monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br /> alarm system. The failed, model 420 91 annular sensor was replaced "like-for-like,"with a Veeder root 420 sensor <br /> (model number: 0794390-420) by an Elite IV technician Jarod Burke (ICC: 1113118, Veeder root: 2121118). The <br /> sensor was replaced and retested during the inspection. The sensor was verified to be working properly. <br /> This was corrected on site. <br /> This is a Class 11 violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The tertiary (rock guard) piping for the fuel lines were open in both the 87 and 91 submersible turbine pump sumps. <br /> The technician installed and tightened the tertiary boots. <br /> This was corrected on site. <br /> The July 14, 2015 secondary containment test results indicate a failure at the 91 annular, UDC 516, and the UDC <br /> 9110. . All secondary containment for the UST system must be tight. Immediately have a properly licensed, trained, <br /> and certified contractor repair or replace the failed component under permit and inspection of the EHD <br /> Failure to resolve this violation may result in a red tag of the underground tanks and will prevent fuel deliveries. <br /> This is a repeat violation, Class ll. <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br /> Liquid was observed in the 91 product tank annular space. If water could enter into the secondary containment by <br /> precipitation or infiltration, it must be removed and disposed of properly. The service technician removed 3 gallons <br /> of liquid from the 91 product tank annular space. Ensure that all sumps and annular spaces are maintained free of <br /> liquid. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> Overall Inspection Comments: <br /> FA0007486 PR050B538 SCO01 03/07/2017 <br /> EHD 23-01 Rev.09/22116 Page 5 of 6 Underground Storage Tank Program OR <br />