My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oul ' Eng F10,AWOR KS <br /> By OPW FUELING CONTAINMENT SYSTEMS <br /> IMPORTANT:Before and after the cou- <br /> pling process,the supplied dust cover 6.2 Dual Series Routing 6.3 Direct Routing <br /> should be kept on the couplings.This pre- This system is used in This system is used in <br /> caution will lessen the possibility of dam- "pressure"systems where "suction"systems where one <br /> age⢠two piping lines interconnect piping line is directly con- <br /> NOTE: When installing swivel couplings,hand tighten the all the dispensers divided nected to only one dispenser <br /> coupling onto the OPW-FCS fitting until it is snug.With an equally. inlet. <br /> OPW-FCS Swivel Wrench,tighten the coupling nut 1/4 turn <br /> more or to 200 in/lbs.Do not allow the pipe to rotate during <br /> tightening.This procedure will prevent over tightening of <br /> the coupling past the maximum 200 in/lbs. <br /> 5.3 Test Caps <br /> These custom threaded plugs have a 1/4"NPT port in the <br /> end for attachment of an air gauge or a valve stem(not in- <br /> cluded).Test caps are used to test the integrity of each pipe <br /> section prior to installation. <br /> 5.4 Test Gauge Assembly 7.0 PIPING DESIGN CRITERIA <br /> This air gauge assembly provides a means of When designing and installing Flex piping systems,use the <br /> testing only the interstitial space of double wall following criteria to insure that they meet OPW-FCS's re- <br /> piping.These gauges connect to the end of the quirements: <br /> test tubes and have a maximum pressure rating 7.1 Piping Turns <br /> of 15 psi. <br /> 5.5 Fishing Bullnose Piping trenches should be cut with sweeping turns.Flexible <br /> piping turns require specific radii depending on the pipe <br /> Attaches to the end of a flexible pipe section in 1:;1diameter.Piping turns should not be less than; <br /> order to fish(push or pull)the flexible pipe sec- <br /> tion through the Access Pipe. Its rounded nose 0.75"-18"Radius <br /> provides an easy means of feeding the pipe 1.0"-18"Radius <br /> through the Access Pipe.The swivel bullnoses are fitted with 1.5"-24"Radius <br /> a metal eyelet for attachment of a plumber's fish.Available in <br /> 1-1/2"and 2"pipe sizes for attachment to both coax pipe 2.0"-3b"Radius <br /> couplings and metallic pipe couplings. 3.0"-72"Radius <br /> 6.0 PRE-INSTALLATION PLANNING 7.2 Piping Crossovers <br /> The type of pipe routing design selected is dependent on-the A minimum compacted layer of either 2"of approved pea <br /> quantity and orientation of the dispensers,the type of sys- gravel or crushed stone or 4"of approved sand backfill must <br /> tem(either pressure or suction)and the layout of the facility. separate each pipe. <br /> One constant design requirement is that all piping that runs 7,3 Piping Supply Capacity <br /> between containment sumps be continuous.Single and dual <br /> piping lines may be used depending on the total quantity of For a pressure piping system using single piping runs routed <br /> dispensers to be serviced and the location and orientation of in seriesr no more than a total of six dispensing nozzles <br /> the islands.The pipe routing design criteria for OPW-FCS's should be serviced with a 1-1/2"single piping line to prevent <br /> flexible piping system is considerably different than that of unacceptable product flow rates.Consult OPWFCS's custom- <br /> conventional rigid piping.For either new or retrofit installa- er service department for flow rate calculations. <br /> tions,good pre-installation planning is a must to insure a 7.4 Vent Piping Fall <br /> proper installation. If Vent Piping is used for vent lines,make sure there is ade- <br /> quate fall back to the tank from the vent stack.OPWFCS re- <br /> 6.1 Single Series Routing quires a minimum 1/8"per foot slope for all vent lines. <br /> This system is used in"pressure" 7.5 Product Sequence <br /> systems where one piping line inter- The dispensing product sequence will alternate from one <br /> connects all of the product dispens- dispenser to the next when"loop-around"is used.Pipe cross- <br /> ers. overs are recommended at these points to correct the <br /> change in product sequence in"series"routing of pressure <br /> piping systems. <br />
The URL can be used to link to this page
Your browser does not support the video tag.