My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar 08 16 01:11 p JP Petroleum Service P16372487 p.2 <br /> SWRC6.January 2002 APR 066 2016Page of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: x Tank Manufacturer D Industry Standard U Professional Engineer <br /> ❑Other(Speq y) <br /> Test Method Used: ❑Pressure x Vacuum D Hydrostatic <br /> ❑Other (Sped) <br /> Test Equipment Used:Dwyer Manometer Equipment Resolution:+1-2% <br /> t20,303 <br /> # 1 Tank# 2 Tank# Tank#o <br /> Is Tank Exempt From Testing?' Yes x NC Yes x No ❑Yes ©No ❑Yes f7 ala <br /> Tank Capacity: 12,424 <br /> Tank Material: Steel Steel <br /> Tank Manufacturer: Unknown Unimown <br /> Product Stored: Premium Regular <br /> Wait time between applying <br /> pressureNacuumlwater and 36 min 30 min 30 ruin 30 min <br /> starting test.- <br /> Test <br /> est:Test Start Time: 9:45 9:45 <br /> Initial Reading(Rj): 7.89 8-92 — <br /> Test End Time: 10:45 10:45 <br /> Finat Reading(RF): 8.41 <br /> Test Duration: I hour 1 hour I hour 1 hour <br /> Change in Reading(RF-Rt): .51 <br /> Pass/Fail Threshold or Criteria: No less than l" No less than t" No less than I" No fess than ]" <br /> Test Result: ❑ Pass x Fail x Pass ❑Fail 11 Pass CJ)Fail ❑ Pass :7 Fail <br /> Was sensor removed for testing? x Yes 0 No DNA x Yes D No ❑NA x Yes �l No ❑NA x Yes ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functionai after testin ? x Yes ❑No ❑NA x Yes G No O NA x Yet �No 0 NA x Yes l7No ❑NA <br /> I OMMeRtS— Onclude information on repairs made prior to resting, and recommended ollow-u pr oiled tests <br /> Premium annular space will not maintain vacuum. <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or tinder constant vacuum,are exempt from periodic containment <br /> testing. f California Code of Regulations, Title 23, Section 2637(a)(6)1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.