My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1789
>
2300 - Underground Storage Tank Program
>
PR0506538
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 9:47:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0506538
PE
2361
FACILITY_ID
FA0007486
FACILITY_NAME
COUNTRY MARKETPLACE
STREET_NUMBER
1789
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16337023
CURRENT_STATUS
01
SITE_LOCATION
1789 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\CHARTER\1789\PR0506538\COMPLIANCE INFO 2016 - PRESENT.pdf
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
11/18/2016 5:11:43 PM
QuestysRecordID
3261353
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FORM ; <br /> '%w UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Pae 1 of 2) 1 <br /> 0-1 <br /> TYPE OF ACTION ❑ 1.NEW PLAN V1 2.CHANGE OF INFORMATION 49 <br /> PLAN TYPE �,1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. a90- <br /> 0-z <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S)- <br /> 1. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) - - I <br /> BUSINESS NAME(Same as FACILITY NAME) 3. <br /> BUSINESS SITE ADDRESS `-7L7>,j w. C y\o.r eT CITYCA <br /> 104. <br /> II,EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR 2632,2634,2639,2641 _ __ <br /> MONITORING EQUIPMENT IS SERVICED [�,1.ANNUALLY El99.OTHER(Specify) 4W3b <br /> III.MONITORING LOCATIONS <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN.Ta2.SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)4944 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 491-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> ------------------------------------------- - - <br /> PANEL MANUFACTURER: 6%� n�,f{.D -- 490-7. MODEL#: T--CA490-9 <br /> LEAK SENSOR MANUFACTURER: eW ,tea 4949. MODEL#(S): 49410 <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATC)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 490-12. MODEL#: 496-13 <br /> -- ---------------- -- - ------- ------ - - --- - - - - - <br /> ----------- <br /> IN-TANK <br /> ---------IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15 <br /> - -- -- ------- ------------- - - - - - - <br /> ------------------------------------- -- <br /> -------- -- <br /> LEAK TEST FREQUENCY: E] a.CONTINUOUS ❑ b.DAILYINIGHTLY ❑ c.WEEKLY 490-16 <br /> ❑ d.MONTHLY ❑ c.OTHER(Specify): 490-17 <br /> - <br /> _----- _____ _._ _ <br /> 49418 <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 490-19 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: F_] a.36 HOURS El b.60 HOURS 49900.22 <br /> ❑ 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 49421 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 49424 <br /> 990-25 <br /> E]99.OTHER (Specify): 426 <br /> 9999 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHODS)(Check all that apply) <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND x9428 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑b.LIQUID FILLED [1c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> - --- -- --------------- - - -- - -- - ------------ - - - .. <br /> PANEL MANUFACTURER: 4943° i_MODEL#: M ----------------------- - 49431 <br /> --------------------------------------1-MOD <br /> LEAK SENSOR MANUFACTURER: �Q,L er - Qo 494sz MODEL#(S) �0 49933 <br /> -- - -------------------------------- ------- - -- ------- ------------------------ <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.c.,TURBINE)SHUTDOWN. ❑a.YES ❑b.NO 49434 <br /> FAILURE/DISCONNECFION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 490-35 <br /> ❑ 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> --_PRODUCT FLOW WHEN A LEAK IS DETECTED 23 CCR 2636 ___-_-__-__-__-_-_ -_- 490-36 <br /> - -----(;3------1-- -�- - - - - - - - - -�j - <br /> MLLD MANUFACTURER(S): M �� 490-37 MODEL#(S): q-{ 490-38 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> ---------------------------------------------------------------------------------------------------------------------------------------- <br /> ELLD MANUFACTURER(S) --- 49440. 3 MODEL#(S)_ <br /> --- -- --------------------------------------------------------------------- -------------------- ------- <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 490-42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49043 <br /> ELLD FAILUREIDISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 490-44 <br /> ❑ 4.PIPE INTEGRITY TESTING 490-45 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 490-46490-47 <br /> ❑ 5.VISUAL PIPE MONITORING. 490-48 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49 <br /> Allowed for mnitwiny of unburied emergemy generatOT fuel piping only er HSC'25281 5 b 3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR 62636(a)(3)]. 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 <br /> ❑ 99.OTHER(Specify) 49952 <br /> 49453 <br />
The URL can be used to link to this page
Your browser does not support the video tag.