Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.slaov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MORADA CHEVRON FAST N EASY#60 10878 N HWY 99 , STOCKTON April 24, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan idicates that the Under <br /> Dispenser Containment(UDC)is performed by a Veeder Root sensor, site is montiored by Bravo float and chain. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). <br /> This was corrected on site. <br /> This is a minor violation. <br /> 121 CCR 2712(f)Failed to submit a written response within 30 days of receiving an inspection report. <br /> An compliance review was last done on March 11, 2017 and a defiency letter was issued identifying information to <br /> be submitted to bring this site into compliance. This information was required to be submitted by April 10, 2017 . <br /> This information has not been received resulting in a non-compliant status for this facility. An operator that receives <br /> an inspection report shall have 30 days to submit a written response that includes a statement documenting <br /> corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br /> documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site.The 2016 Monitoring <br /> Certification Report and the 2015 secondary Containment Test report were not found oniste. These records shall <br /> be maintained on site for at least three years. Monitoring records include: (1)date and time of all monitoring or <br /> sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other monitoring <br /> equipment, ground water elevations, or other test results; (6)results of inventory readings and reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This was corrected on site. <br /> This is a minor violation. <br /> FA0001146 PR0231598 SCO01 04/24/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />