99 (STATE ROUTE 99)
>
14800
>
2300 - Underground Storage Tank Program
>
PR0231600
>
COMPLIANCE INFO_1986-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:11 PM
Creation date
11/8/2018 9:48:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2008
RECORD_ID
PR0231600
PE
2361
FACILITY_ID
FA0000957
FACILITY_NAME
LATHROP GAS & FOOD MART*
STREET_NUMBER
14800
Direction
S
STREET_NAME
STATE ROUTE 99
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19702004
CURRENT_STATUS
02
SITE_LOCATION
14800 S HWY 99 RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\14800\PR0231600\COMPLIANCE INFO 1986-2008.PDF
QuestysFileName
COMPLIANCE INFO 1986-2008
QuestysRecordDate
8/30/2017 6:29:37 PM
QuestysRecordID
3613342
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
375
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> Paged of� <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facili is Not E ui ed With Fill Riser Containment Sum s <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Me od Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> 11 Other(Specify) <br /> Test Equipment Ised: Equipment Resolution: <br /> Fill Sump# Fill Sump# Fill Sump# Fill Sum # <br /> Sum Diameter: p <br /> Sum De the <br /> Height from Tank Top to Top of <br /> Hi est Pi in Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testin : <br /> Portion of Sum Tested <br /> Sum Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Readin Rt <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Chan a in Readin R,-R, <br /> Pass/Fail Threshold or Criter' . <br /> Test Resultse : ❑ Pass ❑Fail ❑ Pass ❑Fail 0 Pass Fail ❑ Pass ❑Fail <br /> Is there a nsor in the p? ❑Yes ❑No ❑Yes ❑No ❑Yes o ❑Yes ❑No <br /> Does the sensor al when <br /> either product or r is ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA Yes ❑No ❑NA <br /> detected? <br /> Was sensor r ovedfor testing7 ❑Yes 0 N ❑NA --Eyes ONO [INA ❑Yes ❑No [INA 0 e 0 N 0 <br /> Was sen r properly replaced and ❑Yes ❑No ❑NA <br /> verifie ctional after testing? <br /> ❑Y� ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> fun <br /> COMMent$—(include information on repairs made prior to testing and recommended follow t p orfailed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.