My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4855
>
2300 - Underground Storage Tank Program
>
PR0506650
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
11/8/2018 9:50:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0506650
PE
2361
FACILITY_ID
FA0007571
FACILITY_NAME
ARCH ARCO AM PM*
STREET_NUMBER
4855
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17926051
CURRENT_STATUS
01
SITE_LOCATION
4855 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\HWY 99\4855\PR0506650\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Illlll]] f• <br /> Appendix VI SEP 1 <br /> MONITORING SYSTEM CERTIFICATION EIMRONN,.. <br /> For Use By All Jurisdictions Within the State of California PER111TBmir.t,cJ <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: ARCH AMPM Bldg.No.: <br /> Site Address: 4855 HWY 99 City: STOCKTON Zip: 95205 <br /> Facility Contact Person: Contact Phone No.: (0) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 02-14-17 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: 87 TanklD: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG t <br /> ® Annular Space or Vault Sensor. Madel: 409 ® Annular Space or Vault Sensor, Model: 409 <br /> ® Piping Sump/Trench Sensols). Model: 323 ® Piping Sump/Trench Sensor(s). Model: 323 <br /> ® Fill Sump Sensor(s). Model: 323 ® Fill Sump Sensols). Model: 323 <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ® Mechanical Line Leak Detector, Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: 90% ® Tank Overfill/High-Level Sensor. Model: 90% <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: 89 Tank ID: NA <br /> ® In-Tank Gauging Probe. Model: MAG t ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 409 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 323 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ® Fill Sump Sensor(s). Model: 344 ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: 99 LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: 90% ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> DispenserlD: 1.2 Dispenser ID: 3.4 <br /> ® Dispenser Containment Seasons). Model: 323 ® Dispenser Containment Sensor(s). Model: 323 <br /> ® Shear Velvets). ® Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 323 ® Dispenser Containment Sensor(s). Model: 323 <br /> ® Shear Velvets). ® Sheer Velvets). <br /> ❑ Dispenser Containment Float(s)and Cl in(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 9-10 DispenserlD: 11-12 <br /> ® Dispenser Containment Sensor(s), Model: 323 ® Dispenser Containment Sensor(s). Model: 323 <br /> ® Shear Valve(s). ®Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks ordispensem,copy this forth. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify thatthe equipment Identified In this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification Is Information(e.g.manufacturers'checklists)necessary to verify that this Information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 02-14-17 <br /> Monitoring System Certification Pagel of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.