San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCH ARCO AM PM' 4855 S HWY 99 E FRONTAGE RD, STOCKTON February 13, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site plan is lacking the approximate location of the <br /> underground storage tank piping.A site plan must be submitted identifying the locations where monitoring will be <br /> performed. Immediately log into the California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov/and upload a revised copy of the UST Monitoring Site Plan. <br /> This is a repeat violation,Class Il. <br /> 110 CCR 2637(e)Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was performed on 6/20/2017 and a test report was submitted on 9/19/2017, 3 <br /> months late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br /> Annual monitoring system certification(MSC)and leak detector testing were performed on February 14, 2016, more <br /> than two months past the due date of November 2015.The annual MSC and leak detector testing should have been <br /> completed in November 2016 and November 2017. Instead the MSC and leak detector testing were completed in <br /> February 2017 and today(February 13, 2018).Testing is more than two months past due.These tests are required <br /> once every 12 months in November.Take all necessary precautions to ensure testing is performed in a timely <br /> manner. <br /> This is a repeat violation, Class ll. <br /> 112 HSC 25284.2 Failed to test spill containers annually. <br /> Annual spill container testing was performed on February 14,2016, more than two months past the due date of <br /> November 2015.The annual spill container testing should have been completed in November 2016 and November <br /> 2017. Instead the spill container testing was completed in February 2017 and today(February 13,2018).Testing is <br /> more than two months past due.These tests are required once every 12 months in November.Take all necessary <br /> precautions to ensure testing is performed in a timely manner. <br /> This is a repeat violation, Class II. <br /> FA0007571 PRO506650 SC001 02/132018 <br /> 5110 23-01 Rev.09122116 Page 4 of 6 underground Storage Tank Program OIR <br />