My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page__of <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: x Tank Manufacturer Industry Standard Professional Engineer <br /> Other(Specify) <br /> Test Method Used: Pressure x Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Dwyer Manometer Equipment Resolution:-i/-2% <br /> Tankr -# I Refuse Tank# Tank# - Tank# <br /> la-I anl, 1 Xempt Flom i Cstutw J� Yes x No Yes No Yes No Yes No - <br /> Tank Capacity: 6,000 <br /> Tank Material: Fiberglass <br /> Tank Manufacturer: Owens Corning <br /> Product Stored: Contact Water <br /> Wait time between applying <br /> pressure/vacuum/water and 30 min 30 min 30 min 30 min <br /> starting test: <br /> Test Start Time: 11:50 <br /> Initial Reading(Rt): 5.50 <br /> Test End Time: 12:50 <br /> Final Reading(RF): 5.07 <br /> Test Duration: 1 hour 1 hour - 1 hour I hour <br /> Change in Reading(RF-Rt): .43 <br /> Pass/Fail Threshold or Criteria: No less than 1" No less than I" No less than I" No less than 1" <br /> Test Result: x Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? x Yes No NA x Yes No NA x Yes No NA x Yes No NA <br /> Was sensor properly replaced andx Yes No NA x Yes No NA x Yes No NA x Yes No NA <br /> verified functional after testing? <br /> Coriunents— (include information on repairs made prior to testing, and recommended folloiv-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.