My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing ,O.CT ,$�O 2014 <br /> Software Version Installed: NA J <br /> Complete the following checklist: <br /> Yes No* Is the audiblealann operational? I <br /> r Yes F- No* Is the sisuaI alai in operational.' <br /> F- Yes Fv No* :Were all sensor,visually inspected, functionally tented,and confirmed operational? <br /> W Yes ( No* Were all sensors instal led at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere w ith their <br /> roper operation'? <br /> r Yes No* If alarms are relayed m a remote monitoring station, all commwiicanons egwpnpent(e g modem) <br /> ( <br /> N/A '.operational? <br /> F Yes r No* For pressurized piping systems, does the turbine automatically shutdown if the pipingsecondary <br /> containment monitoring system detects a leak, fails to operate, or is electrically disconnected?Ifyes:which <br /> F N/A sensors initiate positive shut-down?(Check all that apply) <br /> r Sump/Trench Sensors; r Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensorfailure/disconnection? <br /> r Yes; r No. <br /> F Yes r No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> N/A tatdc fill point(s)and operating properly?If so, at what percent of tank capacity does the alarm trigger? <br /> 80 "o <br /> vYes* (— No Was any monitoring equ ip inent replaced' If yes,identify is w pecific sensors, probes.of other eqpip ent <br /> i replaced and list the manufacat er nameand model for all replacement parts up Sect ton E,helot4 <br /> Yes* No Was Itqu d found inside any secondary containment systems designed as dry systems'? (Check all that <br /> apply) r Product, Water.If yes,describe causes m Section E, below. <br /> 'firv * Was monitoring System Set-Up reviewed to ensure roper settings?Attach s <br /> Yes � No g Y- P P I b-? set up reports rf applicable <br /> F Yes F- No* Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E belme,describe how and when thesedeliciencies were orwill be corrected. <br /> E. Comments: <br /> Other sensors from page one: <br /> Transition Sump Sensor Certified: LS-3A <br /> The LS3 overfill alarm sensor was replaced,like for like,and then certified. <br /> Piping Sump Sensor Certified:LS3 (could not be tested during Annual Certification due to confined space issues). <br />
The URL can be used to link to this page
Your browser does not support the video tag.