My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing ) <br /> D <br /> Software Version Installed: NA <br /> Complete the following checklist: OCT 16 2014 <br /> F Yes r No* Is the audiblealarm operational? ENVIRONMENTAL HEALT <br /> F Yes r No* Is the visual alarm operational? <br /> F Yes r No* Were all sensors visually inspected, functionally tested,andconfinnedoperational? <br /> F Yes r No* Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> ro r operation? <br /> r Yes r No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem) <br /> N/A operational? <br /> r Yes r No* Forpressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> F N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected?lfyes: which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> F Sump/frenchSensors; r Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> r Yes; r No. <br /> r Yes r No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> F N/A mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> F Yes* r No Was any monitoring equipment replaced?If yes,identify specific sensors,probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E,below. <br /> F Yes* 1 No Was liquid found inside arty secondary containment systems designed as dry systems? (Check all that <br /> apply) r Product; r Water.If yes,describe causes in Section E,below. <br /> F Yes r No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> r Yes r No* Is all monitoring equipment operational permanufacrnrer's specifications? <br /> *In SectionE below,describe how and when these de6dencies were orwill be corrected <br /> E. Comments: <br /> Other sensors from page one: <br /> Transition Sump ULS: Certified. <br /> The LS3 overfill alarm did not function and needs to be replaced: Failed. <br /> Could Not Test Piping Sump Sensor(LS3) Due to Confined Space. <br />
The URL can be used to link to this page
Your browser does not support the video tag.