My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> I 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> I Telephone: (209)468-3420 Fax:(209)468-3433 Web:www sjaov org/ehd <br /> Underground Storage Tank Program inspection Report <br /> Facility Name: Facility Address: <br /> Shell Oil Products US -Stockton Terminal 3515 Nav Date: <br /> Navy Dr, Stockton September 29, 2014 <br /> On Site Records <br /> PE2712(2712(b) Failed to maintain records of monitoring,repair, lining,and upgrades on site n V n R n COS <br /> 1) Current monitoring plan approved by the EHD not found on site ■V n R n COS <br /> 205 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame ❑V ❑R ❑COS <br /> 206 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed u V ❑R ❑COS <br /> 207 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months o V ❑R ❑COS <br /> 208 CCR 2715(f) Designated operator employee training not performed or log not kept ❑V ❑R n COS <br /> 209 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑V ❑R ❑COS <br /> 210 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R ❑COS <br /> 211 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept u V u R LCOS <br /> UST System Observations <br /> 301 HSC 25291.1 UST system is not operated to prevent unauthorized release,including spills and overfills ■V ❑R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) n V n R n COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003Jun 2004) ❑V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) u V u R u COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained ❑V ❑R ❑COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity n V ❑R n COS <br /> 307 CCR 2632(x) Monitoring system of the interstitial space of a double walled system not maintained ❑V ❑R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V ❑R ❑COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC ❑V ❑R ❑COS <br /> 310 CCR 2636(0(1) Sensor in a piping sump failed to activate an audible and visual alarm or stop the flow product ❑V ❑R ❑COS <br /> 311 CCR 2636(0(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs ❑V ❑R ❑COS <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment ❑V ❑R ❑COS <br /> 313 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V ❑R ❑COS <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003) ❑V ❑R ❑COS <br /> 315 HSC 25290.2(x)(1) Primary containment not tight(Jul 2003-Jun2004) n V n R n COS <br /> 316 HSC 25290.1(x)(1) Primary containment not tight(after Jun 2004) ❑V n R n COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight ❑V ❑R ❑COS <br /> 25291 <br /> 318 CCR 2636(a) Failed to have secondary containment ❑V u R ❑COS <br /> 319 HSC 25291(a) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ❑V ❑R ❑COS <br /> 320 HSC 25290.1(x3), Secondary containment not constructed to prevent water intrusion n V n R n COS <br /> 25290.1 c3 <br /> 321 CCR 2636(x)(1) All releases in secondary piping do not flow to a collection sump ❑V o R o COS <br /> ;Received <br /> 636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi n V n R n COS <br /> 635(b) No spill bucket installed or failed to provide a means to keep it empty n V ❑-R ,COS <br /> initial): Inspector: Phone: pate: <br /> MICHELLE HENRY, Senior REHS (209)468-3454 09/29/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.