My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO 2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 1:54:23 PM
Creation date
11/8/2018 9:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2006-2015.PDF
QuestysFileName
COMPLIANCE INFO 2006-2015
QuestysRecordDate
8/4/2017 7:52:05 PM
QuestysRecordID
3555178
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www sjgov org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: <br /> Shell Oil Products US -Stockton Terminal 3515 Navy Dr, Stockton Date: <br /> September 29, 2014 <br /> UST System Observations <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons <br /> o u ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements <br /> n u ❑COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status <br /> o c ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag <br /> u c ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST <br /> u o ❑COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms <br /> o o ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored <br /> u o ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements <br /> ❑V ❑R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements <br /> ❑V o ❑COS <br /> Non-Pressurized Piping <br /> [2060See <br /> 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve <br /> ❑V o ❑COS <br /> 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed <br /> a u ❑COS <br /> 643(d) Triennial 0.1 gph line test for conventional suction piping not performed re-Janus 1984 <br /> (p ry ) ❑V ❑R ❑COS <br /> 643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) <br /> o o ❑COS <br /> Other Violations <br /> elow Unlisted Administration/Documentation violation <br /> ❑V n ❑COS <br /> elow Unlisted Operations/Maintenance violation <br /> o a ❑COS <br /> elow Unlisted Design/Construction violation <br /> ❑V o ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 104 UST Operating Permit Application for Facility and Tank information not submitted or current. UST Facility Operating <br /> Permit is not current in CERS, the facility ID should be FA0003747. Any change of information must be updated in <br /> CERS within 30 days of the changes. Immediately log into CERS, update the required information, and submit for <br /> review by the EHD. <br /> UST Tank Information forms for the"slop" UST is not current in CERS. Please review the following and make <br /> necessary changes: Tank ID, piping sump, vent and vapor recovery piping construction, piping/turbine containment <br /> sump, vent piping transition sump, and fill components. Any change of information must be updated in CERS within 30 <br /> days of the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> The above listed violations are Class II <br /> 106 Monitoring and response plans not current or approved by the EHD. The monitoring plan is not current and/or not <br /> approved by the EHD. Please review pipe monitoring and personnel responsibilities and make necessary changes. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log into <br /> rCERS, make the necessary changes, and submit for review by the EHD. Minor violation <br /> 204Current monitoring plan approved by the EHD not found on site. An approved copy of the monitoring plans were not <br /> available for inspection. A copy of these plans shall be accessible on site at all times. Immediately locate and retain a <br /> copy on site. Minor violation <br /> Received bY(initial): Inspector: Phone: r <br /> Jate: <br /> MICHELLE HENRY, Senior REHS (209) 468-3454 , 09/29/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.