My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:47 PM
Creation date
11/8/2018 9:50:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2016-PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016-PRESENT
QuestysRecordDate
8/4/2017 7:45:17 PM
QuestysRecordID
3555111
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />September 21, 2017 <br /> Facility Address: <br /> 3515 Navy Dr, Stockton <br /> Facility Name: <br /> Shell Oil Products US - Stockton Terminal <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />UST System Observations <br /> 323 □ V □ R □ COSUnburied below grade UST system failed to meet exemption statusHSC 25283.5(a) <br /> 324 □ V □ R □ COSTampered with red tagCCR 2717.1(g) <br /> 325 □ V □ R □ COSDeposited petroleum into a red tagged USTCCR 2717.1(f) <br /> 326 □ V □ R □ COSTampered with or disabled leak detection devices or alarmsHSC 25299(a)(9) <br /> 327 □ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1 <br /> 328 □ V □ R □ COSFailed to comply with temporary closure requirementsHSC 25298 <br /> 329 □ V □ R □ COSFailed to comply with permanent closure requirementsHSC 25298 <br /> 330 □ V □ R □ COSFailure to meet all requirements in lieu of a line leak detector for emergency generator tank systemCCR 2636(f)(6) <br />Single-Walled Non-Pressurized Piping <br /> 401 □ V □ R □ COSSuction piping not properly sloped or incorrectly located check valveCCR 2636(a)(3) <br /> 402 □ V □ R □ COSDaily monitoring of suction pipe (pre-Jan 1984) not performedCCR 2643(d) <br /> 403 □ V □ R □ COSTriennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984)CCR 2643(d) <br /> 404 □ V □ R □ COSBiennial 0.1 gph test for gravity piping not performed (pre-January 1984)CCR 2643(e) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 2030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 2060 □ V □ R □ COSUnlisted Design/Construction violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. Under "Other Pipeline Monitoring" it is stated <br />that "Piping Transition Sump Sensor: EBW LS-3A" is being used. Per technician on site and label on sensor the <br />"Piping Transition Sump Sensor" is an Incon ULS . The monitoring plan must be uploaded to the California <br />Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br />for review by the EHD. <br />This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The sensor in the "Transition Sump" is labeled as an <br />"LS-3A". The sensor in the sump is an Incon ULS sensor, per technician on site and label on sensor. A site plan <br />must be submitted identifying the locations where monitoring will be performed. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />Page 3 of 4 <br />FA0003747 PR0231210 SC001 09/21/2017 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR
The URL can be used to link to this page
Your browser does not support the video tag.