My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2300 - Underground Storage Tank Program
>
PR0231210
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:47 PM
Creation date
11/8/2018 9:50:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231210
PE
2361
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\N\NAVY\3515\PR0231210\COMPLIANCE INFO 2016-PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016-PRESENT
QuestysRecordDate
8/4/2017 7:45:17 PM
QuestysRecordID
3555111
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />September 21, 2017 <br /> Facility Address: <br /> 3515 Navy Dr, Stockton <br /> Facility Name: <br /> Shell Oil Products US - Stockton Terminal <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br />The "Contact Water" annular sensor failed to activate an audible and visual alarm when tested and, therefore, the <br />tank is not monitored. The interstitial space shall be monitored with a monitoring system connected to an audible <br />and visual alarm system. The sensor was replaced and retested during the inspection. A “UST Retrofit Verification <br />with Inspector Already Onsite” form has been completed and provided to the operator and contractor. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by October 21, 2017. <br />Note: The spill container did not hold 5 gallons. When the spill container fails, replace the spill container with <br />one that has a minimum capacity of 5 gallon, is protected from corrosion and has either a drain valve which <br />allows drainage of the collected spill into the primary container or provides a means to keep the spill container <br />empty pursuant to California Code of Regulations Title 22 section 2635(b)(1) <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Inspector Phone: <br /> (209) 953-6213 CESAR RUVALCABA, EHS Trainee <br /> Inspector:September 21, 2017 Date: <br />Printed Name and Title: <br />Richard Bronson, Operations Coordinator <br />Page 4 of 4 <br />FA0003747 PR0231210 SC001 09/21/2017 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR
The URL can be used to link to this page
Your browser does not support the video tag.