Laserfiche WebLink
Page 1 of 1 <br /> v 1.01 <br /> Aris Cacapit [EH] <br /> From: Alexia Inigues [ainigues@barghausen.com] <br /> Sent: Monday, December 17, 2012 2:49 PM <br /> To: Aris Cacapit[EH] <br /> Cc: Briana Armstrong; File; Omar Vasquez; Chris Tebaldi <br /> Subject: revised application documents per your last comments for Lodi Fuel Additive/ BCE#14573 <br /> Importance: High <br /> Attachments: 14573-F-APPL-San Joaquin County ENVT-UST Install-2012-12-17-Revised.pdf; 14573-F-APPL- <br /> Monitoring Plan Tank#4-2012-12-17.pdf <br /> Aris, I discussed the comment you made with Omar to use the overfill prevention at 90%. This is the <br /> route Costco would like to proceed instead of having the contractor provide the calculations and the <br /> tank chart. Please confirm that the changes to the Monitoring Plan and the application form <br /> Monitoring Plan Change: <br /> X. CONINIE TS ADDITION Ai. INFOWNTATION <br /> Provide additional comments here or indicate how manv Paves with adchhoaai information op specific moaitoriae procedures are art <br /> Overfill alarm set at W%for overfill protection <br /> \T VVWR IXWT RV4ZP(1WgTRTTTTTFG <br /> Application form Change: PAGE 7 OF APPLICATION <br /> G. OVERSPILLI OVERFILL PREVENTION: <br /> X ge tie Ovarapai contamment havo9 masmum caphacth'of 5 gailans provided at each txan fel Weill m. <br /> Manufacturer OPW Mo" <br /> Approved overfill prevention device provdded at each tank fill location. <br /> choose One of the following methods: <br /> X Alert the transfer aperatto when the pink Is 90 Percent oy reslnt"V me OWN kno to has Of <br /> v4genng an audVe casual alarm <br /> Restrict dekvety of aver to tN tank at last 30 meutes betdro the lank ovW(ft,provided UN' <br /> �a� restripaon occas vAhen the tank n raked to ne moa than 95 WOW"Panay,and acbvats an <br /> ;X 7aaa4aka/ audible Hann ar least ave minutes before the tank vsedffs <br /> Provde posante shutrttow to the tank,~the tank a Med to m n edhan 95 perp ft d <br /> oapacny <br /> Provide positwe shmt off of flaw to the hank so that none of the faPwnps khcated on the top of the <br /> tank are exposed to Pxw d�ro <br /> Manu#safer VEE9Ek ROOT Md arorsu,over rwflrh ver vaso ar+�vers west-.av <br /> Thank you. <br /> Alexia Inigues, Project Planner <br /> usen Consulting Engineers, Inc. <br /> 18215 RECEIVED <br /> 18215 72"d Ave South <br /> Kent, WA 98032 <br /> Direct) 425.656.7430 - Office) 425.251.6222 - Celll 206.255.4794 <br /> ainigues@barghausen.com DEC 1 7 2012 <br /> (�Please consider the environment before printing this email. <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL <br /> HEALTH DEPARTMENT <br /> 12/19/2012 <br />