My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:41:30 PM
Creation date
11/8/2018 9:53:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\R\REYNOLDS RANCH\2680\PR0535432\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aris Cacapit, REHS <br /> San Joaquin County <br /> Environmental Health Department -2- December 4, 2012 <br /> • Site Map T4 of 12 #33 list a hydrostatic sensor-single float, Veeder-Root model <br /> #VR-794380-301. Change to hydrostatic sensor-dual float, Veeder Root model <br /> # VR-794380-303 <br /> Response: The sensor has been revised on sheet T4. Also enclosed is a copy of the <br /> correct cut sheet to be included in the set of cut sheets sent in our original submittal <br /> • Monitoring Plan line 490-10 change to 794380-303. <br /> Response: The Tank 4 Monitoring Plan line item 490-10 has been revised to reference <br /> 794380-303 <br /> • The cut sheet for parts 50, 51, 52, and 53 refer to a F-Series Rigid Fiberglass Fittings for <br /> SINGLEWALL fiberglass sumps. Revise the site map T4 of 12#50, 51, 52, and 53 to include <br /> fittings for DOUBLEWALL sumps. <br /> Response: Sheet T4 has been revised to reflect the correct fittings. Also enclosed is the <br /> correct cut sheet for double-wall fiberglass sump entry fittings. Please add the correct cut <br /> sheet to the set included in our original submittal <br /> • Application for underground storage tank installation permit, page 8, section 1. Monitoring, At <br /> the bottom of the interstitial space of each secondarily-contained tank, positioned as near as <br /> possible to the bottom of the tank. Manufacturer Veeder-root Model 794380-301. Change to <br /> 794380-303. <br /> Response: Page 8 Section I. Monitoring item in the Application for Underground <br /> Storage Tank Installation Permit form has been revised to reference 794380-303. <br /> Pursuant to your conversation with Briana Armstrong of this office, we have added a note to the <br /> Comments Section of the Tank 4 Monitoring Plan indicating that mechanical flapper is set at 95% for <br /> overfill protection. <br /> We believe that the above responses, together with the enclosed documentation, address all of your <br /> comments. Please review and approve the enclosed at your earliest convenience. If you have questions <br /> or need additional information, please do not hesitate to contact me at this office. Thank you. <br /> Respectfully, <br /> ,j/M.Alexia"Inigues <br /> Project Planner <br /> MAI/jss <br /> 14573c.029.doc <br /> enc: As Noted <br /> cc: David H Rogers, Costco Wholesale <br /> Jay S. Grubb, Barghausen Consulting Engineers, Inc. <br /> Daniel B. Goalwin, Barghausen Consulting Engineers, Inc. <br /> John Ellingsen, Barghausen Consulting Engineers, Inc. <br /> Chris M. Tebaldi, Barghausen Consulting Engineers, Inc. <br /> Briana L. Armstrong, Barghausen Consulting Engineers, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.